High-Frequency (1000 Hz) Tympanometry in Normal Neonates
Joseph Kei, Julie Allison-Levick, Jacqueline Dockray, Rachel Harrys, Christina Kirkegard, Janet Yuen Ha Wong, Marion Maurer, Jayne Hegarty, June Young, David Tudehope
Abstract
Joseph Kei, Julie Allison-Levick, Jacqueline Dockray, Rachel Harrys, Christina Kirkegard, Janet Yuen Ha Wong, Marion Maurer, Jayne Hegarty, June Young, David Tudehope
Abstract
The characteristics of high frequency (1000 Hz) acoustic admittance results obtained from normal neonates were described in this study. Participants were 170 healthy neonates (96 boys and 74 girls) aged between 1 and 6 days (mean = 3.26 days, SD = 0.92). Transient evoked otoacoustic emissions (TEOAEs), and 226 Hz and 1000 Hz probe tone tympanograms were obtained from the participants using a Madsen Capella OAE/middle ear analyser. The results showed that of the 170 neonates, 34 were not successfully tested in both ears, 14 failed the TEOAE screen in one or both ears, and 122 (70 boys, 52 girls) passed the TEOAE screen in both ears and also maintained an acceptable probe seal during tympanometry. The 1000 Hz tympanometric data for the 122 neonates (244 ears) showed a single-peaked tympanogram in 225 ears (92.2 %), a flat-sloping tympanogram in 14 ears (5.7 %), a double-peaked tympanogram in 3 ears (1.2 %) and other unusual shapes in 2 ears (0.8 %). There was a significant ear effect, with right ears showing significantly higher mean peak compensated static admittance and tympanometric width, but lower mean acoustic admittance at +200 daPa and gradient than left ears. No significant gender effects or its interaction with ear were found. The normative tympanometric data derived from this cohort may serve as a guide for detecting middle ear dysfunction in neonates. El estudio describe las caracterrsticas de la admitancia acústica de alta frecuencia (1000 Hz) obtenida en neonatos normales. Los participantes fueron 170 neonatos saludables (26 niños y 74 niñas) con edades entre 1 y 6 días (media de 3.26, SD = 0.92). Se obtuvieron emisiones otoacústicas evocadas por transientes (TEOAE) y timpanogramas realizados con una sonda de prueba de 226 Hz y 1000 Hz usando una unidad Madsen Capella con un analizador de oído medio y EOA. Los resultados mostraron que de los 170 neonatos, 34 no pudieron ser evaluados en ambos oídos, 14 fallaron la prueba de TEOAE en uno o en ambos oídos, y 122 (70 niños y 52 niñas) pasaron el tamizaje de TEOAE en ambos oídos y también mantuvieron un nivel de sello aceptable en la sonda de timpanometría. La información timpanométrica a 1000 Hz para los 122 neonatos (244 oídos) mostró un timpanograma de pico único en 225 oídos (32.2%), un timpanograma plano con pendiente en 14 oídos (5.7%), un timpanograma de doble pico en 3 ordos (1.2%), y otras forma inusuales en 2 ordos (0.8%). Existió un significativo efecto de oído, con los oídos derechos mostrando picos medios compensados de admitancia estática y anchos timpanométricos significativamente mayores, aunque gradientes y admitancias acústica promedio menores a + 200 daPa, en oídos izquierdos. No se encontró un significativo efecto de género o de género por oído. La información normativa timpanométrica de esta cohorte puede servir como una guí a para detectar disfunción de oído medio en neonatos.
OpenAlex reports 134 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The characteristics of high frequency (1000 Hz) acoustic admittance results obtained from normal neonates were described in this study. Participants were 170 healthy neonates (96 boys and 74 girls) aged between 1 and 6 days (mean = 3.26 days, SD = 0.92). Transient evoked otoacoustic emissions (TEOAEs), and 226 Hz and 1000 Hz probe tone tympanograms were obtained from the participants using a Madsen Capella OAE/middle ear analyser. The results showed that of the 170 neonates, 34 were not successfully tested in both ears, 14 failed the TEOAE screen in one or both ears, and 122 (70 boys, 52 girls) passed the TEOAE screen in both ears and also maintained an acceptable probe seal during tympanometry. The 1000 Hz tympanometric data for the 122 neonates (244 ears) showed a single-peaked tympanogram in 225 ears (92.2 %), a flat-sloping tympanogram in 14 ears (5.7 %), a double-peaked tympanogram in 3 ears (1.2 %) and other unusual shapes in 2 ears (0.8 %). There was a significant ear effect, with right ears showing significantly higher mean peak compensated static admittance and tympanometric width, but lower mean acoustic admittance at +200 daPa and gradient than left ears. No significant gender effects or its interaction with ear were found. The normative tympanometric data derived from this cohort may serve as a guide for detecting middle ear dysfunction in neonates. El estudio describe las caracterrsticas de la admitancia acústica de alta frecuencia (1000 Hz) obtenida en neonatos normales. Los participantes fueron 170 neonatos saludables (26 niños y 74 niñas) con edades entre 1 y 6 días (media de 3.26, SD = 0.92). Se obtuvieron emisiones otoacústicas evocadas por transientes (TEOAE) y timpanogramas realizados con una sonda de prueba de 226 Hz y 1000 Hz usando una unidad Madsen Capella con un analizador de oído medio y EOA. Los resultados mostraron que de los 170 neonatos, 34 no pudieron ser evaluados en ambos oídos, 14 fallaron la prueba de TEOAE en uno o en ambos oídos, y 122 (70 niños y 52 niñas) pasaron el tamizaje de TEOAE en ambos oídos y también mantuvieron un nivel de sello aceptable en la sonda de timpanometría. La información timpanométrica a 1000 Hz para los 122 neonatos (244 oídos) mostró un timpanograma de pico único en 225 oídos (32.2%), un timpanograma plano con pendiente en 14 oídos (5.7%), un timpanograma de doble pico en 3 ordos (1.2%), y otras forma inusuales en 2 ordos (0.8%). Existió un significativo efecto de oído, con los oídos derechos mostrando picos medios compensados de admitancia estática y anchos timpanométricos significativamente mayores, aunque gradientes y admitancias acústica promedio menores a + 200 daPa, en oídos izquierdos. No se encontró un significativo efecto de género o de género por oído. La información normativa timpanométrica de esta cohorte puede servir como una guí a para detectar disfunción de oído medio en neonatos.
Key concepts: Tympanometry, Audiology, Medicine, Middle ear, Admittance, Hearing loss, Audiometry, Surgery