Monitoring myoglobin by capillary zone electrophoresis with end-column amperometric detection

Wenrui Jin, Qian Dong, Daiqing Yu, Xiaoyin Ye

Open publisher page 14 citations

Abstract

Capillary zone electrophoresis was employed for the determination of myoglobin in human urine using end-column amperometric detection with a carbon fiber microelectrode at a constant potential of 1.80 V vs. saturated calomel electrode (SCF). The optimum conditions of separation and detection are: 3.73 x 10-4 mol/L sodium diethyl malonyl urea (barbitone sodium), 1.34 x 10-4 mol/L HCl for the buffer solution, 20 kV for separation voltage, 5 kV and 5 s for injection voltage and injection time, respectively. The limit of detection is 4.4 x 10-8 mol/L or 84 amole signal to noise (S/N = 2). The relative standard deviation is 2.9% for the migration time and 2.5% for the electrophoretic peak current. The method can be used for the determination of myoglobin in human urine. The samples can be directly injected and need no pretreatment. The method is also rapid, less than 2 min, and has a recovery rate of 94-106%.

About this research paper

What this paper is about

Capillary zone electrophoresis was employed for the determination of myoglobin in human urine using end-column amperometric detection with a carbon fiber microelectrode at a constant potential of 1.80 V vs. saturated calomel electrode (SCF). The optimum conditions of separation and detection are: 3.73 x 10-4 mol/L sodium diethyl malonyl urea (barbitone sodium), 1.34 x 10-4 mol/L HCl for the buffer solution, 20 kV for separation voltage, 5 kV and 5 s for injection voltage and injection time, respectively. The limit of detection is 4.4 x 10-8 mol/L or 84 amole signal to noise (S/N = 2). The relative standard deviation is 2.9% for the migration time and 2.5% for the electrophoretic peak current. The method can be used for the determination of myoglobin in human urine. The samples can be directly injected and need no pretreatment. The method is also rapid, less than 2 min, and has a recovery rate of 94-106%.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Capillary zone electrophoresis was employed for the determination of myoglobin in human urine using end-column amperometric detection with a carbon fiber microelectrode at a constant potential of 1.80 V vs. saturated calomel electrode (SCF). The optimum conditions of separation and detection are: 3.73 x 10-4 mol/L sodium diethyl malonyl urea (barbitone sodium), 1.34 x 10-4 mol/L HCl for the buffer solution, 20 kV for separation voltage, 5 kV and 5 s for injection voltage and injection time, respectively. The limit of detection is 4.4 x 10-8 mol/L or 84 amole signal to noise (S/N = 2). The relative standard deviation is 2.9% for the migration time and 2.5% for the electrophoretic peak current. The method can be used for the determination of myoglobin in human urine. The samples can be directly injected and need no pretreatment. The method is also rapid, less than 2 min, and has a recovery rate of 94-106%.

Key concepts: Myoglobin, Capillary electrophoresis, Amperometry, Chromatography, Capillary action, Chemistry, Capillary electrochromatography, Electrophoresis