2014The International Journal of Oral & Maxillofacial ImplantsRequires access

Titanium Tattooing Associated with Zirconia Implant Abutments: A Clinical Report of Two Cases

Thomas N. Taylor, Michael W Klotz, Rodger Lawton

Open publisher page 35 citations

Abstract

Worn particulate titanium abraded from a titanium dental implant that discolors the adjacent soft tissues has not previously been reported. Two cases of this gingival tissue "tattooing" are reported here. While the use of zirconia abutments in areas of high esthetic concern is widespread, the effects of particulate titanium being worn from the implant by the much harder abutment material and then taken up in the adjacent soft tissues should be considered as a potential complication and a consideration when selecting the type of abutment to be used.

About this research paper

What this paper is about

Worn particulate titanium abraded from a titanium dental implant that discolors the adjacent soft tissues has not previously been reported. Two cases of this gingival tissue "tattooing" are reported here. While the use of zirconia abutments in areas of high esthetic concern is widespread, the effects of particulate titanium being worn from the implant by the much harder abutment material and then taken up in the adjacent soft tissues should be considered as a potential complication and a consideration when selecting the type of abutment to be used.

Why it matters

OpenAlex reports 35 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Worn particulate titanium abraded from a titanium dental implant that discolors the adjacent soft tissues has not previously been reported. Two cases of this gingival tissue "tattooing" are reported here. While the use of zirconia abutments in areas of high esthetic concern is widespread, the effects of particulate titanium being worn from the implant by the much harder abutment material and then taken up in the adjacent soft tissues should be considered as a potential complication and a consideration when selecting the type of abutment to be used.

Key concepts: Abutment, Titanium, Implant, Dentistry, Soft tissue, Dental Abutments, Cubic zirconia, Dental implant

Related papers

Back to paper searchBrowse research topicsOriginal source
Titanium Tattooing Associated with Zirconia Implant Abutments: A Clinical Report of Two Cases — Research Paper | ScholarLens