2008Clinical Oral Implants ResearchRequires access

Two‐year prospective clinical comparison of immediate replacement vs. immediate restoration of single tooth in the esthetic zone

Piermario Palattella, Ferruccio Torsello, Luca Cordaro

Open publisher page 123 citations

Abstract

AIM: To compare the immediate restoration of single implants in the esthetic zones performed on implants placed immediately after tooth extraction or 8 weeks later (immediate replacement vs. immediate restoration). METHODS: Sixteen patients (10 women and 6 men) with a mean age of 35 years (ranging from 21 to 49 years old) were treated from 2004 to 2005 for single-tooth replacement in the upper arch. The patients were randomly divided into two groups: in the test group patients received implants placed and restored (non-occlusal loading) at the time of tooth extraction; in the control group implants were placed 8 weeks after tooth extraction and immediately restored. All the patients received tapered effect (TE) implants from the Straumann Dental Implant System. The following parameters were evaluated at the moment of provisional restoration (within 48 h after implant placement) and at the 2 years follow-up visit: marginal bone resorption, papilla index, position of the mucosal margin. The implant stability quotient was measured at the moment of implant placement and at the moment of the delivery of the definitive restoration. RESULTS: No statistically significant differences were found in any of the studied parameters between the test and the control groups (P>0.05). The implant stability quotient values between the test and control groups were significant (P<0.05) at the moment of implant placement but were no more significant at the loading of the definitive restoration (P>0.05). CONCLUSION: The results of the present study suggest that immediate replacement without functional loading may be considered a valuable therapeutic option for selected cases of single-tooth replacement in the esthetic area when TE implants are used. Implant stability at the moment of implant placement is slightly inferior in the immediate replacement group, but it does not affect the treatment result.

About this research paper

What this paper is about

AIM: To compare the immediate restoration of single implants in the esthetic zones performed on implants placed immediately after tooth extraction or 8 weeks later (immediate replacement vs. immediate restoration). METHODS: Sixteen patients (10 women and 6 men) with a mean age of 35 years (ranging from 21 to 49 years old) were treated from 2004 to 2005 for single-tooth replacement in the upper arch. The patients were randomly divided into two groups: in the test group patients received implants placed and restored (non-occlusal loading) at the time of tooth extraction; in the control group implants were placed 8 weeks after tooth extraction and immediately restored. All the patients received tapered effect (TE) implants from the Straumann Dental Implant System. The following parameters were evaluated at the moment of provisional restoration (within 48 h after implant placement) and at the 2 years follow-up visit: marginal bone resorption, papilla index, position of the mucosal margin. The implant stability quotient was measured at the moment of implant placement and at the moment of the delivery of the definitive restoration. RESULTS: No statistically significant differences were found in any of the studied parameters between the test and the control groups (P>0.05). The implant stability quotient values between the test and control groups were significant (P<0.05) at the moment of implant placement but were no more significant at the loading of the definitive restoration (P>0.05). CONCLUSION: The results of the present study suggest that immediate replacement without functional loading may be considered a valuable therapeutic option for selected cases of single-tooth replacement in the esthetic area when TE implants are used. Implant stability at the moment of implant placement is slightly inferior in the immediate replacement group, but it does not affect the treatment result.

Why it matters

OpenAlex reports 123 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

AIM: To compare the immediate restoration of single implants in the esthetic zones performed on implants placed immediately after tooth extraction or 8 weeks later (immediate replacement vs. immediate restoration). METHODS: Sixteen patients (10 women and 6 men) with a mean age of 35 years (ranging from 21 to 49 years old) were treated from 2004 to 2005 for single-tooth replacement in the upper arch. The patients were randomly divided into two groups: in the test group patients received implants placed and restored (non-occlusal loading) at the time of tooth extraction; in the control group implants were placed 8 weeks after tooth extraction and immediately restored. All the patients received tapered effect (TE) implants from the Straumann Dental Implant System. The following parameters were evaluated at the moment of provisional restoration (within 48 h after implant placement) and at the 2 years follow-up visit: marginal bone resorption, papilla index, position of the mucosal margin. The implant stability quotient was measured at the moment of implant placement and at the moment of the delivery of the definitive restoration. RESULTS: No statistically significant differences were found in any of the studied parameters between the test and the control groups (P>0.05). The implant stability quotient values between the test and control groups were significant (P<0.05) at the moment of implant placement but were no more significant at the loading of the definitive restoration (P>0.05). CONCLUSION: The results of the present study suggest that immediate replacement without functional loading may be considered a valuable therapeutic option for selected cases of single-tooth replacement in the esthetic area when TE implants are used. Implant stability at the moment of implant placement is slightly inferior in the immediate replacement group, but it does not affect the treatment result.

Key concepts: Implant stability quotient, Dentistry, Medicine, Implant, Orthodontics, Dental implant, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Two‐year prospective clinical comparison of immediate replacement vs. immediate restoration of single tooth in the esthetic zone — Research Paper | ScholarLens