1990RADIOISOTOPESOpen access

Solid scintillator "Ready Cap" for measurement with a liquid scintillation counter. Spectra and counting efficiencies for 15 different radionuclides.

Kenichi Ijiri, Masashi Endo, Susumu Osaki, Norio Nogawa, Shoko TSUDA, Aiko NAKAMURA, Naotake MORIKAWA

Open full text 0 citations

Abstract

"Ready Cap", a small plastic container coated with solid scintillator has recently been introduced (Beckman Instruments, Inc.). Pulse height spectra and counting efficiencies obtained with a liquid scintillator and Ready Cap using a liquid scintillator counter were compared for 15 different radionuclides. For radionuclides emitting low-energy beta-rays or characteristic X-rays, the spectra for Ready Cap shifted toward the higher energy side compared with the spectra for the liquid scintillator. This tendency was reversed for the nuclides emitting higher-energy beta-radiations (36Cl and 32P). Generally, counting efficiencies both in Ready Cap and in liquid scintillator increased with increase in the energy of beta- or X-rays. For some nuclides, Ready Cap gave higher counting efficiencies and for others it gave lower values than in the liquid scintillator. However, the differences were not large within each nuclide. The use of Ready Cap is recommended for measurements of radionuclides when liquid scintillation cocktails have no means of waste disposal under the present Japanese radioisotope regulation.

Open-access reader

About this research paper

What this paper is about

"Ready Cap", a small plastic container coated with solid scintillator has recently been introduced (Beckman Instruments, Inc.). Pulse height spectra and counting efficiencies obtained with a liquid scintillator and Ready Cap using a liquid scintillator counter were compared for 15 different radionuclides. For radionuclides emitting low-energy beta-rays or characteristic X-rays, the spectra for Ready Cap shifted toward the higher energy side compared with the spectra for the liquid scintillator. This tendency was reversed for the nuclides emitting higher-energy beta-radiations (36Cl and 32P). Generally, counting efficiencies both in Ready Cap and in liquid scintillator increased with increase in the energy of beta- or X-rays. For some nuclides, Ready Cap gave higher counting efficiencies and for others it gave lower values than in the liquid scintillator. However, the differences were not large within each nuclide. The use of Ready Cap is recommended for measurements of radionuclides when liquid scintillation cocktails have no means of waste disposal under the present Japanese radioisotope regulation.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

"Ready Cap", a small plastic container coated with solid scintillator has recently been introduced (Beckman Instruments, Inc.). Pulse height spectra and counting efficiencies obtained with a liquid scintillator and Ready Cap using a liquid scintillator counter were compared for 15 different radionuclides. For radionuclides emitting low-energy beta-rays or characteristic X-rays, the spectra for Ready Cap shifted toward the higher energy side compared with the spectra for the liquid scintillator. This tendency was reversed for the nuclides emitting higher-energy beta-radiations (36Cl and 32P). Generally, counting efficiencies both in Ready Cap and in liquid scintillator increased with increase in the energy of beta- or X-rays. For some nuclides, Ready Cap gave higher counting efficiencies and for others it gave lower values than in the liquid scintillator. However, the differences were not large within each nuclide. The use of Ready Cap is recommended for measurements of radionuclides when liquid scintillation cocktails have no means of waste disposal under the present Japanese radioisotope regulation.

Key concepts: Scintillator, Liquid scintillation counting, Radionuclide, Scintillation counter, Radiochemistry, Scintillation, Alpha-particle spectroscopy, Spectral line

Related papers

Back to paper searchBrowse research topicsOriginal source
Solid scintillator "Ready Cap" for measurement with a liquid scintillation counter. Spectra and counting efficiencies for 15 different radionuclides. — Research Paper | ScholarLens