1982The Journal of Infectious DiseasesRequires access

Correlation of Serum Bactericidal Activity with Antimicrobial Agent Level and Minimal Bactericidal Concentration

Charles W. Stratton, Melvin P. Weinstein, L. Barth Reller

Open publisher page 59 citations

Abstract

Few data are available to show how serum dilution test results correlate with results of antimicrobial assays and determinations of minimal inhibitory concentrations (MICs) and minimal bactericidal concentrations (MBCs). Serum dilution tests were performed for 65 patients with bacteremia from serious infections. Assays for antimicrobial agent levels and determinations fo MICs and MBCs against the infecting organisms were performed simultaneously. Mueller-Hinton broth and Mueller-Hinton broth supplemented with Ca++, Mg++, and pooled human serum were compared as diluents for the serum either medium yielded positive correlations, better correlations were found between measured and expected serum bactericidal activities when both ther serum dilution test dilutions and the MIC and MBC determinations were done in the supplemented MHB-human serum solution.

About this research paper

What this paper is about

Few data are available to show how serum dilution test results correlate with results of antimicrobial assays and determinations of minimal inhibitory concentrations (MICs) and minimal bactericidal concentrations (MBCs). Serum dilution tests were performed for 65 patients with bacteremia from serious infections. Assays for antimicrobial agent levels and determinations fo MICs and MBCs against the infecting organisms were performed simultaneously. Mueller-Hinton broth and Mueller-Hinton broth supplemented with Ca++, Mg++, and pooled human serum were compared as diluents for the serum either medium yielded positive correlations, better correlations were found between measured and expected serum bactericidal activities when both ther serum dilution test dilutions and the MIC and MBC determinations were done in the supplemented MHB-human serum solution.

Why it matters

OpenAlex reports 59 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Few data are available to show how serum dilution test results correlate with results of antimicrobial assays and determinations of minimal inhibitory concentrations (MICs) and minimal bactericidal concentrations (MBCs). Serum dilution tests were performed for 65 patients with bacteremia from serious infections. Assays for antimicrobial agent levels and determinations fo MICs and MBCs against the infecting organisms were performed simultaneously. Mueller-Hinton broth and Mueller-Hinton broth supplemented with Ca++, Mg++, and pooled human serum were compared as diluents for the serum either medium yielded positive correlations, better correlations were found between measured and expected serum bactericidal activities when both ther serum dilution test dilutions and the MIC and MBC determinations were done in the supplemented MHB-human serum solution.

Key concepts: Antimicrobial, Minimum bactericidal concentration, Microbiology, Anti-Infective Agents, Medicine, Chemistry, Minimum inhibitory concentration, Biology

Related papers

Back to paper searchBrowse research topicsOriginal source
Correlation of Serum Bactericidal Activity with Antimicrobial Agent Level and Minimal Bactericidal Concentration — Research Paper | ScholarLens