1997Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIERequires access

ROC study of screen-film mammography and storage phosphor digital mammography: analysis of nonconcordant classifications and implications for the approval of digital mammography systems

Matthew T. Freedman, Dorothy Steller Artz, Jacquelyn P. Hogge, Rebecca A. Zuurbier, Hamid Jafroudi, Shih‐Chung B. Lo, Seong K. Mun

Open publisher page 1 citations

Abstract

A recently completed ROC study of digital mammography using a 100 micron pixel storage phosphor receptor showed that digital mammography and conventional screen film mammography were essentially equivalent in areas under the ROC curve. In this study, there were 24 biopsy proven breast cancer cases, 25 benign biopsy cases and 48 clinically normal breast images each with matched screen film and storage phosphor images. Fifteen of the 24 cancer cases were 10 mm or less in size. Of these 10 presented with microcalcifications as the sign of disease. Six radiologists not involved with the research program and without prior experience with digital mammography and who met qualification criteria under the Mammography Quality Standards Act of 1992 served as readers. This poster looks at the cases in which there was variance between the radiologists ROC classification system for the digital and screen film system in order to analyze case specific discrepancies that may indicate benefits or deficits of the digital system. Aspects of the ROC ratings are also analyzed including an evaluation of the different thresholds used by radiologists on the digital and screen film systems, the distribution of ROC ratings in normal and abnormal cases, the effect of using different gold standards of proof on the results and the effect of substituting an ACR BIRADS category agreement study as proposed by the FDA compared to the ROC study outcome.

About this research paper

What this paper is about

A recently completed ROC study of digital mammography using a 100 micron pixel storage phosphor receptor showed that digital mammography and conventional screen film mammography were essentially equivalent in areas under the ROC curve. In this study, there were 24 biopsy proven breast cancer cases, 25 benign biopsy cases and 48 clinically normal breast images each with matched screen film and storage phosphor images. Fifteen of the 24 cancer cases were 10 mm or less in size. Of these 10 presented with microcalcifications as the sign of disease. Six radiologists not involved with the research program and without prior experience with digital mammography and who met qualification criteria under the Mammography Quality Standards Act of 1992 served as readers. This poster looks at the cases in which there was variance between the radiologists ROC classification system for the digital and screen film system in order to analyze case specific discrepancies that may indicate benefits or deficits of the digital system. Aspects of the ROC ratings are also analyzed including an evaluation of the different thresholds used by radiologists on the digital and screen film systems, the distribution of ROC ratings in normal and abnormal cases, the effect of using different gold standards of proof on the results and the effect of substituting an ACR BIRADS category agreement study as proposed by the FDA compared to the ROC study outcome.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A recently completed ROC study of digital mammography using a 100 micron pixel storage phosphor receptor showed that digital mammography and conventional screen film mammography were essentially equivalent in areas under the ROC curve. In this study, there were 24 biopsy proven breast cancer cases, 25 benign biopsy cases and 48 clinically normal breast images each with matched screen film and storage phosphor images. Fifteen of the 24 cancer cases were 10 mm or less in size. Of these 10 presented with microcalcifications as the sign of disease. Six radiologists not involved with the research program and without prior experience with digital mammography and who met qualification criteria under the Mammography Quality Standards Act of 1992 served as readers. This poster looks at the cases in which there was variance between the radiologists ROC classification system for the digital and screen film system in order to analyze case specific discrepancies that may indicate benefits or deficits of the digital system. Aspects of the ROC ratings are also analyzed including an evaluation of the different thresholds used by radiologists on the digital and screen film systems, the distribution of ROC ratings in normal and abnormal cases, the effect of using different gold standards of proof on the results and the effect of substituting an ACR BIRADS category agreement study as proposed by the FDA compared to the ROC study outcome.

Key concepts: Digital mammography, Mammography, Medicine, Breast cancer, Receiver operating characteristic, Medical physics, Radiology, Cancer

Related papers

Back to paper searchBrowse research topicsOriginal source
ROC study of screen-film mammography and storage phosphor digital mammography: analysis of nonconcordant classifications and implications for the approval of digital mammography systems — Research Paper | ScholarLens