Direct determinations of 13 rare earth elements (La, Ce, Pr, Nd, Sm, Gd, Tb, Dy, Ho, Er, Yb, Lu and Y) in high purity europium oxide by inductively coupled plasma mass spectrometry (ICP-MS) have been reported. The operating parameters of the instrument were optimized and the spectral interferences and the matrix effects were investigated. Using Ga or Rh as the internal standard can eliminate most of the matrix effects. The detection limits (3 sigma, n=10, integral time=1s) are 0.013-0.085 ng mL(-1) and the reproducibility (n=11) is 0.9-3%. The recoveries of spiking samples are 80-108%. Europium oxide standard material was made and its concentration values were evaluated by various techniques from 10 collaborating laboratories. By comparison of the results of ICP-MS with the results of other techniques, we have validated that ICP-MS is an accurate and reliable technique for analysis of ultratrace impurities in high purity rare earth matrix.

About this research paper

What this paper is about

Direct determinations of 13 rare earth elements (La, Ce, Pr, Nd, Sm, Gd, Tb, Dy, Ho, Er, Yb, Lu and Y) in high purity europium oxide by inductively coupled plasma mass spectrometry (ICP-MS) have been reported. The operating parameters of the instrument were optimized and the spectral interferences and the matrix effects were investigated. Using Ga or Rh as the internal standard can eliminate most of the matrix effects. The detection limits (3 sigma, n=10, integral time=1s) are 0.013-0.085 ng mL(-1) and the reproducibility (n=11) is 0.9-3%. The recoveries of spiking samples are 80-108%. Europium oxide standard material was made and its concentration values were evaluated by various techniques from 10 collaborating laboratories. By comparison of the results of ICP-MS with the results of other techniques, we have validated that ICP-MS is an accurate and reliable technique for analysis of ultratrace impurities in high purity rare earth matrix.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Direct determinations of 13 rare earth elements (La, Ce, Pr, Nd, Sm, Gd, Tb, Dy, Ho, Er, Yb, Lu and Y) in high purity europium oxide by inductively coupled plasma mass spectrometry (ICP-MS) have been reported. The operating parameters of the instrument were optimized and the spectral interferences and the matrix effects were investigated. Using Ga or Rh as the internal standard can eliminate most of the matrix effects. The detection limits (3 sigma, n=10, integral time=1s) are 0.013-0.085 ng mL(-1) and the reproducibility (n=11) is 0.9-3%. The recoveries of spiking samples are 80-108%. Europium oxide standard material was made and its concentration values were evaluated by various techniques from 10 collaborating laboratories. By comparison of the results of ICP-MS with the results of other techniques, we have validated that ICP-MS is an accurate and reliable technique for analysis of ultratrace impurities in high purity rare earth matrix.