1989•Critical Care MedicineRequires access

Noninvasive assessment of cardiac output by impedance cardiography in the newborn canine

Robert W. Gotshall, Daniel S. Miles

Open publisher page 9 citations

Abstract

Currently, critical care monitoring of cardiac function in the newborn human consists mainly of measuring heart rate and BP. A noninvasive technique for assessing cardiac output routinely in the critically ill neonate would facilitate clinical management. Impedance cardiography (IC) is a noninvasive technique which measures stroke volume on a beat-by-beat basis. This study compared cardiac output as measured by thermodilution (TD) to that measured by IC in seven canine pups 6 to 7 days old weighing 0.66 to 0.86 kg. Cardiac output was altered by the withdrawal and reinfusion of blood. There were no significant differences between the two methods for either the absolute value of cardiac output (r = .96) or the percent change in cardiac output (r = .97). Coefficients of variation were 3.0% for TD and 3.6% for IC. These results indicate that IC can be used to assess serially cardiac function in the newborn.

About this research paper

What this paper is about

Currently, critical care monitoring of cardiac function in the newborn human consists mainly of measuring heart rate and BP. A noninvasive technique for assessing cardiac output routinely in the critically ill neonate would facilitate clinical management. Impedance cardiography (IC) is a noninvasive technique which measures stroke volume on a beat-by-beat basis. This study compared cardiac output as measured by thermodilution (TD) to that measured by IC in seven canine pups 6 to 7 days old weighing 0.66 to 0.86 kg. Cardiac output was altered by the withdrawal and reinfusion of blood. There were no significant differences between the two methods for either the absolute value of cardiac output (r = .96) or the percent change in cardiac output (r = .97). Coefficients of variation were 3.0% for TD and 3.6% for IC. These results indicate that IC can be used to assess serially cardiac function in the newborn.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Currently, critical care monitoring of cardiac function in the newborn human consists mainly of measuring heart rate and BP. A noninvasive technique for assessing cardiac output routinely in the critically ill neonate would facilitate clinical management. Impedance cardiography (IC) is a noninvasive technique which measures stroke volume on a beat-by-beat basis. This study compared cardiac output as measured by thermodilution (TD) to that measured by IC in seven canine pups 6 to 7 days old weighing 0.66 to 0.86 kg. Cardiac output was altered by the withdrawal and reinfusion of blood. There were no significant differences between the two methods for either the absolute value of cardiac output (r = .96) or the percent change in cardiac output (r = .97). Coefficients of variation were 3.0% for TD and 3.6% for IC. These results indicate that IC can be used to assess serially cardiac function in the newborn.

Key concepts: Impedance cardiography, Medicine, Cardiac output, Stroke volume, Cardiac function curve, Cardiology, Internal medicine, Heart rate

Related papers

Back to paper searchBrowse research topicsOriginal source
Noninvasive assessment of cardiac output by impedance cardiography in the newborn canine — Research Paper | ScholarLens