1999International Journal of Environmental & Analytical ChemistryRequires access

Simultaneous Determination of Cr(III) and Cr(VI) in Ground and Drinking Waters by IC-ICP-MS

Frank Sacher, Brigitte Raue, Josef Klinger, Heinz‐Jürgen Brauch

Open publisher page 22 citations

Abstract

The coupling of ion chromatography (IC) and inductively-coupled plasma mass spectrometry (ICP-MS) provides a powerful tool for the simultaneous determination of Cr(III) and Cr(VI) in water samples. The experimental set-up of the technique is described in detail and performance data are given, whereby detection limits of 0.1 μg/l could be achieved for both chromium species without pre-concentration. With this method, a complete analysis can be done in less than 3 minutes. In order to improve the repeatability of the method, Rh(III) as internal standard is used. Stability of the two chromium species in water turned out to be a major problem and optimal conditions for storage were determined. For real water samples storage at 4 °C in the dark at neutral pH and analysis as fast as possible is recommended. The application of the IC-ICP-MS technique to real water samples and the comparison to another, more time-demanding and less sensitive method proves the capacity of the method.

About this research paper

What this paper is about

The coupling of ion chromatography (IC) and inductively-coupled plasma mass spectrometry (ICP-MS) provides a powerful tool for the simultaneous determination of Cr(III) and Cr(VI) in water samples. The experimental set-up of the technique is described in detail and performance data are given, whereby detection limits of 0.1 μg/l could be achieved for both chromium species without pre-concentration. With this method, a complete analysis can be done in less than 3 minutes. In order to improve the repeatability of the method, Rh(III) as internal standard is used. Stability of the two chromium species in water turned out to be a major problem and optimal conditions for storage were determined. For real water samples storage at 4 °C in the dark at neutral pH and analysis as fast as possible is recommended. The application of the IC-ICP-MS technique to real water samples and the comparison to another, more time-demanding and less sensitive method proves the capacity of the method.

Why it matters

OpenAlex reports 22 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The coupling of ion chromatography (IC) and inductively-coupled plasma mass spectrometry (ICP-MS) provides a powerful tool for the simultaneous determination of Cr(III) and Cr(VI) in water samples. The experimental set-up of the technique is described in detail and performance data are given, whereby detection limits of 0.1 μg/l could be achieved for both chromium species without pre-concentration. With this method, a complete analysis can be done in less than 3 minutes. In order to improve the repeatability of the method, Rh(III) as internal standard is used. Stability of the two chromium species in water turned out to be a major problem and optimal conditions for storage were determined. For real water samples storage at 4 °C in the dark at neutral pH and analysis as fast as possible is recommended. The application of the IC-ICP-MS technique to real water samples and the comparison to another, more time-demanding and less sensitive method proves the capacity of the method.

Key concepts: Repeatability, Chromium, Inductively coupled plasma mass spectrometry, Chemistry, Mass spectrometry, Detection limit, Chromatography, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous Determination of Cr(III) and Cr(VI) in Ground and Drinking Waters by IC-ICP-MS — Research Paper | ScholarLens