Initial proof-of-concept results obtained in a pilot transonic tunnel, led to a U.S. decision to apply the cryogenic tunnel concept to the National Transonic Facility (NTF). The pilot tunnel was reclassified as a 'permanent' facility and renamed the 0.3-m Transonic Cryogenic Tunnel (TCT). The 0.3-m TCT, with its ability to operate at temperatures ranging from about 78 K to 340 K, combined with a 6 atmospheres pressure capability, provides extremely high test Reynolds numbers at relatively low model loading. In addition, the ability to vary pressure and temperature independently of Mach number provides a unique capability to conduct studies at a constant dynamic pressure or at a constant Reynolds number with just one model. Attention is given to the simulation of flight conditions, the cryogenic-pressure tunnel concept, the characteristics of the 0.3-m TCT, Reynolds number studies in the three-dimensional test section including a Space Shuttle study, and Reynolds number studies in the two-dimensional test section.

About this research paper

What this paper is about

Initial proof-of-concept results obtained in a pilot transonic tunnel, led to a U.S. decision to apply the cryogenic tunnel concept to the National Transonic Facility (NTF). The pilot tunnel was reclassified as a 'permanent' facility and renamed the 0.3-m Transonic Cryogenic Tunnel (TCT). The 0.3-m TCT, with its ability to operate at temperatures ranging from about 78 K to 340 K, combined with a 6 atmospheres pressure capability, provides extremely high test Reynolds numbers at relatively low model loading. In addition, the ability to vary pressure and temperature independently of Mach number provides a unique capability to conduct studies at a constant dynamic pressure or at a constant Reynolds number with just one model. Attention is given to the simulation of flight conditions, the cryogenic-pressure tunnel concept, the characteristics of the 0.3-m TCT, Reynolds number studies in the three-dimensional test section including a Space Shuttle study, and Reynolds number studies in the two-dimensional test section.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Initial proof-of-concept results obtained in a pilot transonic tunnel, led to a U.S. decision to apply the cryogenic tunnel concept to the National Transonic Facility (NTF). The pilot tunnel was reclassified as a 'permanent' facility and renamed the 0.3-m Transonic Cryogenic Tunnel (TCT). The 0.3-m TCT, with its ability to operate at temperatures ranging from about 78 K to 340 K, combined with a 6 atmospheres pressure capability, provides extremely high test Reynolds numbers at relatively low model loading. In addition, the ability to vary pressure and temperature independently of Mach number provides a unique capability to conduct studies at a constant dynamic pressure or at a constant Reynolds number with just one model. Attention is given to the simulation of flight conditions, the cryogenic-pressure tunnel concept, the characteristics of the 0.3-m TCT, Reynolds number studies in the three-dimensional test section including a Space Shuttle study, and Reynolds number studies in the two-dimensional test section.

Key concepts: Transonic, Aerospace engineering, Reynolds number, Subsonic and transonic wind tunnel, Wind tunnel, Aeronautics, Physics, Mechanics

Related papers

Back to paper searchBrowse research topicsOriginal source
A review of Reynolds number studies conducted in the Langley 0.3-m Transonic Cryogenic Tunnel — Research Paper | ScholarLens