1985British Journal of DermatologyRequires access

Comparison of ultrasound and caliper measurements of normal and inflamed skin thickness

Clifford M. Lawrence, Sam Shuster

Open publisher page 32 citations

Abstract

We have compared ultrasound and Harpenden calipers for the measurement of thickness of non-inflamed and anthralin-inflamed skin. In non-inflamed skin ultrasound gave consistently and significantly lower values (0.87 mm +/- 2.3% s.e.) than calipers (1.1 mm +/- 2.7% s.e.) and the ultrasound/caliper ratio was 0.89 +/- 1.3%. In anthralin-inflamed skin the ultrasound/caliper ratio was not significantly different from unity (1.02 +/- 1.3%), but ultrasound was unable to measure inflamed skin thickness in 18% of cases because the echo could not detect the dermis-subcutaneous fat interface. The proportion of unreadable ultrasound results increased linearly with increase in skin thickness and the variance of ultrasound readings increased as inflammatory skin thickness increased; by contrast caliper variance remained constant. Harpenden calipers cannot be used in all subjects or in skin sites in which skin folds cannot be raised, but if the patient and site to be studied can be selected, Harpenden calipers have a greater precision, reproducibility and reliability than ultrasound for measurement of the thickness of inflamed skin.

About this research paper

What this paper is about

We have compared ultrasound and Harpenden calipers for the measurement of thickness of non-inflamed and anthralin-inflamed skin. In non-inflamed skin ultrasound gave consistently and significantly lower values (0.87 mm +/- 2.3% s.e.) than calipers (1.1 mm +/- 2.7% s.e.) and the ultrasound/caliper ratio was 0.89 +/- 1.3%. In anthralin-inflamed skin the ultrasound/caliper ratio was not significantly different from unity (1.02 +/- 1.3%), but ultrasound was unable to measure inflamed skin thickness in 18% of cases because the echo could not detect the dermis-subcutaneous fat interface. The proportion of unreadable ultrasound results increased linearly with increase in skin thickness and the variance of ultrasound readings increased as inflammatory skin thickness increased; by contrast caliper variance remained constant. Harpenden calipers cannot be used in all subjects or in skin sites in which skin folds cannot be raised, but if the patient and site to be studied can be selected, Harpenden calipers have a greater precision, reproducibility and reliability than ultrasound for measurement of the thickness of inflamed skin.

Why it matters

OpenAlex reports 32 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We have compared ultrasound and Harpenden calipers for the measurement of thickness of non-inflamed and anthralin-inflamed skin. In non-inflamed skin ultrasound gave consistently and significantly lower values (0.87 mm +/- 2.3% s.e.) than calipers (1.1 mm +/- 2.7% s.e.) and the ultrasound/caliper ratio was 0.89 +/- 1.3%. In anthralin-inflamed skin the ultrasound/caliper ratio was not significantly different from unity (1.02 +/- 1.3%), but ultrasound was unable to measure inflamed skin thickness in 18% of cases because the echo could not detect the dermis-subcutaneous fat interface. The proportion of unreadable ultrasound results increased linearly with increase in skin thickness and the variance of ultrasound readings increased as inflammatory skin thickness increased; by contrast caliper variance remained constant. Harpenden calipers cannot be used in all subjects or in skin sites in which skin folds cannot be raised, but if the patient and site to be studied can be selected, Harpenden calipers have a greater precision, reproducibility and reliability than ultrasound for measurement of the thickness of inflamed skin.

Key concepts: Calipers, Ultrasound, Medicine, Reproducibility, Skin thickness, Dermis, Biomedical engineering, Anatomy

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of ultrasound and caliper measurements of normal and inflamed skin thickness — Research Paper | ScholarLens