Rotavirus Detection Using Ultrasound Enhanced Latex Agglutination and Turbidimetry
Michael A. Sobanski, R. W. B. Ellis, J. G. M. Hastings
Abstract
Michael A. Sobanski, R. W. B. Ellis, J. G. M. Hastings
Abstract
Application of a non-cavitating ultrasonic standing wave to suspended microparticles brings the particles into close approximation and has been used previously to enhance the performance of several diagnostic agglutination tests. The sensitivity of rotavirus detection by ultrasound enhanced latex agglutination was compared with conventional test-card agglutination. Application of ultrasound gave a 32-fold improvement in the sensitivity of detection of rotavirus antigen in buffer compared with the test card method. A novel turbidimetric approach was used to measure agglutination occurring following the test-card procedure (in place of visual examination) and following exposure of commercial rotavirus latex reagents to a 4.5 MHz ultrasonic field (in place of microscopy). The sensitivity enhancement over the conventional method achievable through ultrasonic exposure was comparable whether agglutination measurements were made visually or turbidimetrically and demonstrates the potential for turbidimetry in combination with the ultrasonic method. Turbidimetry offers an alternative to visual assessment that may be more easily incorporated into automated systems.
OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Application of a non-cavitating ultrasonic standing wave to suspended microparticles brings the particles into close approximation and has been used previously to enhance the performance of several diagnostic agglutination tests. The sensitivity of rotavirus detection by ultrasound enhanced latex agglutination was compared with conventional test-card agglutination. Application of ultrasound gave a 32-fold improvement in the sensitivity of detection of rotavirus antigen in buffer compared with the test card method. A novel turbidimetric approach was used to measure agglutination occurring following the test-card procedure (in place of visual examination) and following exposure of commercial rotavirus latex reagents to a 4.5 MHz ultrasonic field (in place of microscopy). The sensitivity enhancement over the conventional method achievable through ultrasonic exposure was comparable whether agglutination measurements were made visually or turbidimetrically and demonstrates the potential for turbidimetry in combination with the ultrasonic method. Turbidimetry offers an alternative to visual assessment that may be more easily incorporated into automated systems.
Key concepts: Turbidimetry, Latex fixation test, Ultrasonic sensor, Agglutination (biology), Direct agglutination test, Ultrasound, Rotavirus, Materials science