2014•Unpublished venueRequires access

Analysis of cable failure modes and cable joint failure detection via sheath circulating current

Xiang Yuan Dong, Yanling Yuan, Zhongqiang Gao, Chengke Zhou, Peter A. Wallace, Babakalli Alkali, Bojie Sheng, Huimeng Zhao

Open publisher page 36 citations

Abstract

Power cables are preferred in urban areas for power transmission and distribution because of their high reliability, environmental friendliness and the visual invisibility. Whilst the volume of underground power cable has been growing steadily, the voltage level of the power cables have also increased significantly in recent years. The increasing volume of high voltage power cables brings about technical challenges to the power system operators and maintenance engineers. One of these challenges is the application of appropriate condition monitoring techniques to detect incipient cable faults and to reduce unplanned outages. This paper aims to analyse the causes, modes and mechanisms, among cable joint failures, and to propose an applicable sheath circulating current monitoring technique with the associated criteria for fault diagnosis. Two joint faults, flooded link box and joint insulation breakdown, are analysed in detail. Finally, a set of criteria is proposed for cable joint fault diagnosis based on the simulation of an 110kV underground power cable system of length 1.5km.

About this research paper

What this paper is about

Power cables are preferred in urban areas for power transmission and distribution because of their high reliability, environmental friendliness and the visual invisibility. Whilst the volume of underground power cable has been growing steadily, the voltage level of the power cables have also increased significantly in recent years. The increasing volume of high voltage power cables brings about technical challenges to the power system operators and maintenance engineers. One of these challenges is the application of appropriate condition monitoring techniques to detect incipient cable faults and to reduce unplanned outages. This paper aims to analyse the causes, modes and mechanisms, among cable joint failures, and to propose an applicable sheath circulating current monitoring technique with the associated criteria for fault diagnosis. Two joint faults, flooded link box and joint insulation breakdown, are analysed in detail. Finally, a set of criteria is proposed for cable joint fault diagnosis based on the simulation of an 110kV underground power cable system of length 1.5km.

Why it matters

OpenAlex reports 36 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Power cables are preferred in urban areas for power transmission and distribution because of their high reliability, environmental friendliness and the visual invisibility. Whilst the volume of underground power cable has been growing steadily, the voltage level of the power cables have also increased significantly in recent years. The increasing volume of high voltage power cables brings about technical challenges to the power system operators and maintenance engineers. One of these challenges is the application of appropriate condition monitoring techniques to detect incipient cable faults and to reduce unplanned outages. This paper aims to analyse the causes, modes and mechanisms, among cable joint failures, and to propose an applicable sheath circulating current monitoring technique with the associated criteria for fault diagnosis. Two joint faults, flooded link box and joint insulation breakdown, are analysed in detail. Finally, a set of criteria is proposed for cable joint fault diagnosis based on the simulation of an 110kV underground power cable system of length 1.5km.

Key concepts: Power cable, Direct-buried cable, Fault (geology), Joint (building), Reliability (semiconductor), Power (physics), Power transmission, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis of cable failure modes and cable joint failure detection via sheath circulating current — Research Paper | ScholarLens