1977CirculationOpen access

Origin of body surface QRS and T wave potentials from epicardial potential distributions in the intact chimpanzee.

Madison S. Spach, Roger C. Barr, C F Lanning, P C Tucek

Open full text 122 citations

Abstract

Epicardial and body surface QRS-T wave potential distributions were measured during normal and ectopic sequences in intact chimpanzees. Epicardial potential distributions were used because they provide a comprehensive picture of total cardiac electrical activity for relating heart and body surface events during both ventricular activation and repolarization. When the epicardial potential gradients existed over a distance greater than that to the recording points on the body surface, e.g., as occurred during the overlap of terminal ventricular activation and early repolarization, the epicardial events were mirrored well on the anterior chest surface. However, when the recording points were at a distance greater than that over which the epicardial potential gradients existed, the details of the epicardial events disappeared and their effect was to produce distinct changes in the low-level potentials over broad distant areas. The major manifestations on the body surface of selective epicardial events frequently were changes in the distant low-level potential areas while there was no change in the pattern near the maximum or minimum. The ST-T wave body surface distributions were as useful as the QRS patterns for localizing the ventricular ectopic foci presented. A direct experimental basis is provided for explaining T wave notches which occurred during normal and ectopic beats and resembled U waves. It should be possible to achieve as precise an understanding of ST-T waves on the basis of epicardial potential distributions as has thus far been achieved for QRS on the basis of isochrones.

Open-access reader

About this research paper

What this paper is about

Epicardial and body surface QRS-T wave potential distributions were measured during normal and ectopic sequences in intact chimpanzees. Epicardial potential distributions were used because they provide a comprehensive picture of total cardiac electrical activity for relating heart and body surface events during both ventricular activation and repolarization. When the epicardial potential gradients existed over a distance greater than that to the recording points on the body surface, e.g., as occurred during the overlap of terminal ventricular activation and early repolarization, the epicardial events were mirrored well on the anterior chest surface. However, when the recording points were at a distance greater than that over which the epicardial potential gradients existed, the details of the epicardial events disappeared and their effect was to produce distinct changes in the low-level potentials over broad distant areas. The major manifestations on the body surface of selective epicardial events frequently were changes in the distant low-level potential areas while there was no change in the pattern near the maximum or minimum. The ST-T wave body surface distributions were as useful as the QRS patterns for localizing the ventricular ectopic foci presented. A direct experimental basis is provided for explaining T wave notches which occurred during normal and ectopic beats and resembled U waves. It should be possible to achieve as precise an understanding of ST-T waves on the basis of epicardial potential distributions as has thus far been achieved for QRS on the basis of isochrones.

Why it matters

OpenAlex reports 122 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Epicardial and body surface QRS-T wave potential distributions were measured during normal and ectopic sequences in intact chimpanzees. Epicardial potential distributions were used because they provide a comprehensive picture of total cardiac electrical activity for relating heart and body surface events during both ventricular activation and repolarization. When the epicardial potential gradients existed over a distance greater than that to the recording points on the body surface, e.g., as occurred during the overlap of terminal ventricular activation and early repolarization, the epicardial events were mirrored well on the anterior chest surface. However, when the recording points were at a distance greater than that over which the epicardial potential gradients existed, the details of the epicardial events disappeared and their effect was to produce distinct changes in the low-level potentials over broad distant areas. The major manifestations on the body surface of selective epicardial events frequently were changes in the distant low-level potential areas while there was no change in the pattern near the maximum or minimum. The ST-T wave body surface distributions were as useful as the QRS patterns for localizing the ventricular ectopic foci presented. A direct experimental basis is provided for explaining T wave notches which occurred during normal and ectopic beats and resembled U waves. It should be possible to achieve as precise an understanding of ST-T waves on the basis of epicardial potential distributions as has thus far been achieved for QRS on the basis of isochrones.

Key concepts: Body surface, QRS complex, Repolarization, Medicine, Cardiology, Benign early repolarization, Internal medicine, Electrophysiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Origin of body surface QRS and T wave potentials from epicardial potential distributions in the intact chimpanzee. — Research Paper | ScholarLens