2012•CorneaRequires access

A Study of Central Corneal Thickness in Glaucoma and Nonglaucoma Patients in a West African Population

Christine Teki Ntim-Amponsah, Adam Y. Seidu, Vera Adobea Essuman, Gladys Fordjour, Naa Naamuah Tagoe, Amin Coker, Leslie Issa Adam-Zakariah

Open publisher page 20 citations

Abstract

PURPOSE: To compare central corneal thickness (CCT) in high-tension glaucomatous eyes and nonglaucomatous eyes with normal intraocular pressure (IOP) and to determine if there is any correlation between CCT and severity of glaucoma, as indicated by vertical cup-to-disc ratio. METHODS: A case-control study that involved 506 subjects at the Korle-Bu Teaching Hospital, Accra, Ghana, from August 2006 to July 2007. The cases were patients with (high tension and IOP more than 21 mm Hg) primary open-angle glaucoma, and the controls were patients with normal IOP (less than 21 mm Hg) and no evidence of glaucoma. The main outcome measures were CCT, as measured by ultrasonic pachymetry (model DGH 55 pachmate), and vertical cup-to-disc ratio. RESULTS: Five hundred six subjects were recruited: 253 cases (506 eyes) and 253 controls (505 eyes). The mean CCT of the right eye for the glaucoma cases was 524.28 μm [95% confidence interval (CI), 4.44; SD, 36.85] and for the controls was 530.00 μm (95% CI, 4.56; SD, 35.75). The mean CCT of the left eye for the glaucoma cases was 524.70 μm (95% CI, 4.48; SD, 36.20) and for the controls was 531.06 μm (95% CI, 4.40; SD, 35.52). The relation between CCT and cupping determined by Pearson correlation coefficient yielded values of -0.09 and 0.01 for the right and left eyes, respectively. CONCLUSION: There was no significant difference between mean CCT of cases and controls in the right eye (P = 0.08), but there was a weakly significant difference in the CCT of the left eye (P = 0.05). Also, there was no correlation between cup-to-disc ratio and CCT.

About this research paper

What this paper is about

PURPOSE: To compare central corneal thickness (CCT) in high-tension glaucomatous eyes and nonglaucomatous eyes with normal intraocular pressure (IOP) and to determine if there is any correlation between CCT and severity of glaucoma, as indicated by vertical cup-to-disc ratio. METHODS: A case-control study that involved 506 subjects at the Korle-Bu Teaching Hospital, Accra, Ghana, from August 2006 to July 2007. The cases were patients with (high tension and IOP more than 21 mm Hg) primary open-angle glaucoma, and the controls were patients with normal IOP (less than 21 mm Hg) and no evidence of glaucoma. The main outcome measures were CCT, as measured by ultrasonic pachymetry (model DGH 55 pachmate), and vertical cup-to-disc ratio. RESULTS: Five hundred six subjects were recruited: 253 cases (506 eyes) and 253 controls (505 eyes). The mean CCT of the right eye for the glaucoma cases was 524.28 μm [95% confidence interval (CI), 4.44; SD, 36.85] and for the controls was 530.00 μm (95% CI, 4.56; SD, 35.75). The mean CCT of the left eye for the glaucoma cases was 524.70 μm (95% CI, 4.48; SD, 36.20) and for the controls was 531.06 μm (95% CI, 4.40; SD, 35.52). The relation between CCT and cupping determined by Pearson correlation coefficient yielded values of -0.09 and 0.01 for the right and left eyes, respectively. CONCLUSION: There was no significant difference between mean CCT of cases and controls in the right eye (P = 0.08), but there was a weakly significant difference in the CCT of the left eye (P = 0.05). Also, there was no correlation between cup-to-disc ratio and CCT.

Why it matters

OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To compare central corneal thickness (CCT) in high-tension glaucomatous eyes and nonglaucomatous eyes with normal intraocular pressure (IOP) and to determine if there is any correlation between CCT and severity of glaucoma, as indicated by vertical cup-to-disc ratio. METHODS: A case-control study that involved 506 subjects at the Korle-Bu Teaching Hospital, Accra, Ghana, from August 2006 to July 2007. The cases were patients with (high tension and IOP more than 21 mm Hg) primary open-angle glaucoma, and the controls were patients with normal IOP (less than 21 mm Hg) and no evidence of glaucoma. The main outcome measures were CCT, as measured by ultrasonic pachymetry (model DGH 55 pachmate), and vertical cup-to-disc ratio. RESULTS: Five hundred six subjects were recruited: 253 cases (506 eyes) and 253 controls (505 eyes). The mean CCT of the right eye for the glaucoma cases was 524.28 μm [95% confidence interval (CI), 4.44; SD, 36.85] and for the controls was 530.00 μm (95% CI, 4.56; SD, 35.75). The mean CCT of the left eye for the glaucoma cases was 524.70 μm (95% CI, 4.48; SD, 36.20) and for the controls was 531.06 μm (95% CI, 4.40; SD, 35.52). The relation between CCT and cupping determined by Pearson correlation coefficient yielded values of -0.09 and 0.01 for the right and left eyes, respectively. CONCLUSION: There was no significant difference between mean CCT of cases and controls in the right eye (P = 0.08), but there was a weakly significant difference in the CCT of the left eye (P = 0.05). Also, there was no correlation between cup-to-disc ratio and CCT.

Key concepts: Ophthalmology, Medicine, Glaucoma, Intraocular pressure, Confidence interval, Normal tension glaucoma, Open angle glaucoma, Optic disc

Related papers

Back to paper searchBrowse research topicsOriginal source
A Study of Central Corneal Thickness in Glaucoma and Nonglaucoma Patients in a West African Population — Research Paper | ScholarLens