Spectrophotometric methods for simultaneous estimation of rabeprazole sodium and aceclofenac from the combined capsule dosage form

Ramesh L. Sawant, Sanket D. Hadawale, Ganesh K. Dhikale, Charusheela A. Bansode, Pravin S. Tajane

Open full text 24 citations

Abstract

INTRODUCTION: The present work aimed to develop and validate spectrophotometric methods for simultaneous estimation of rabeprazole sodium and aceclofenac in a pure and capsule dosage form. MATERIALS AND METHODS: Method 1 is based on solving a simultaneous equation. Absorbances of rabeprazole sodium and aceclofenac were measured at their respective absorbance maximas (λ max) of 283 and 276 nm. Method 2 is the Q-analysis or absorption ratio method. Absorbances were measured at 256 nm (isosbestic point) and 276 nm (λ max of aceclofenac). Methods are validated according to ICH guidelines. RESULTS: A linearity range for rabeprazole sodium and aceclofenac is 10-60 μg/ml at respective selected wavelengths. The coefficient of correlation for rabeprazole at 283 nm and for aceclofenac at 276 nm is 0.9981 and 0.9997, respectively. A percentage estimation of rabeprazole sodium and aceclofenac from the capsule dosage form by method 1 is 100.22 and 99.96 and by method 2 is 99.99 and 100.05, respectively, with a standard deviation less than 2. CONCLUSION: The proposed methods are simple, rapid, and validated and can be used successfully for routine simultaneous estimation of rabeprazole sodium and aceclofenac in a pure and capsule dosage form.

About this research paper

What this paper is about

INTRODUCTION: The present work aimed to develop and validate spectrophotometric methods for simultaneous estimation of rabeprazole sodium and aceclofenac in a pure and capsule dosage form. MATERIALS AND METHODS: Method 1 is based on solving a simultaneous equation. Absorbances of rabeprazole sodium and aceclofenac were measured at their respective absorbance maximas (λ max) of 283 and 276 nm. Method 2 is the Q-analysis or absorption ratio method. Absorbances were measured at 256 nm (isosbestic point) and 276 nm (λ max of aceclofenac). Methods are validated according to ICH guidelines. RESULTS: A linearity range for rabeprazole sodium and aceclofenac is 10-60 μg/ml at respective selected wavelengths. The coefficient of correlation for rabeprazole at 283 nm and for aceclofenac at 276 nm is 0.9981 and 0.9997, respectively. A percentage estimation of rabeprazole sodium and aceclofenac from the capsule dosage form by method 1 is 100.22 and 99.96 and by method 2 is 99.99 and 100.05, respectively, with a standard deviation less than 2. CONCLUSION: The proposed methods are simple, rapid, and validated and can be used successfully for routine simultaneous estimation of rabeprazole sodium and aceclofenac in a pure and capsule dosage form.

Why it matters

OpenAlex reports 24 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

INTRODUCTION: The present work aimed to develop and validate spectrophotometric methods for simultaneous estimation of rabeprazole sodium and aceclofenac in a pure and capsule dosage form. MATERIALS AND METHODS: Method 1 is based on solving a simultaneous equation. Absorbances of rabeprazole sodium and aceclofenac were measured at their respective absorbance maximas (λ max) of 283 and 276 nm. Method 2 is the Q-analysis or absorption ratio method. Absorbances were measured at 256 nm (isosbestic point) and 276 nm (λ max of aceclofenac). Methods are validated according to ICH guidelines. RESULTS: A linearity range for rabeprazole sodium and aceclofenac is 10-60 μg/ml at respective selected wavelengths. The coefficient of correlation for rabeprazole at 283 nm and for aceclofenac at 276 nm is 0.9981 and 0.9997, respectively. A percentage estimation of rabeprazole sodium and aceclofenac from the capsule dosage form by method 1 is 100.22 and 99.96 and by method 2 is 99.99 and 100.05, respectively, with a standard deviation less than 2. CONCLUSION: The proposed methods are simple, rapid, and validated and can be used successfully for routine simultaneous estimation of rabeprazole sodium and aceclofenac in a pure and capsule dosage form.

Key concepts: Aceclofenac, Chemistry, Absorbance, Capsule, Rabeprazole, Chromatography, Sodium, Biochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Spectrophotometric methods for simultaneous estimation of rabeprazole sodium and aceclofenac from the combined capsule dosage form — Research Paper | ScholarLens