A synchrotron-enhanced Fourier transform infrared (SR–FTIR) specializes in combining the tremendous power, brightness, intensity, focusability, and tunability of the photons radiated by a synchrotron with FTIR ability to research the vibrational properties of the lighter elements (i.e., C, N, O, etc.). Infrared (IR) wavelengths correspond to the sizes of molecular bonds having these lighter elements, and only species for which IR photons alter the molecule's dipole moment are detectable and considered to be IR responsive. SR–FTIR excels over traditional FTIR at examining the detailed properties of IR-responsive molecules. Further, SR–FTIR has superior signal-to-noise ratios, brightness, and ability to conduct long-duration scans without altering sample properties. A SR–FTIR scan can reveal exacting molecular details, unrivaled by traditional FTIR. IR-responsive species best analyzed by SR–FTIR can include trace elements, chemical structures, biological specimens, chemical reactions (pump-probe), small or dilute specimens, and molecular matrices. A SR–FTIR is especially likely to give results that have greater precision than traditional FTIR for submonolayers, polymers, semiconductors, superconductors, and environmental samples. Increasingly, the SR–FTIR is used by forensics researchers to examine potential evidentiary materials, such as drugs, paints, fibers, explosives, polymers, inks, documents, blood, and soil.

About this research paper

What this paper is about

A synchrotron-enhanced Fourier transform infrared (SR–FTIR) specializes in combining the tremendous power, brightness, intensity, focusability, and tunability of the photons radiated by a synchrotron with FTIR ability to research the vibrational properties of the lighter elements (i.e., C, N, O, etc.). Infrared (IR) wavelengths correspond to the sizes of molecular bonds having these lighter elements, and only species for which IR photons alter the molecule's dipole moment are detectable and considered to be IR responsive. SR–FTIR excels over traditional FTIR at examining the detailed properties of IR-responsive molecules. Further, SR–FTIR has superior signal-to-noise ratios, brightness, and ability to conduct long-duration scans without altering sample properties. A SR–FTIR scan can reveal exacting molecular details, unrivaled by traditional FTIR. IR-responsive species best analyzed by SR–FTIR can include trace elements, chemical structures, biological specimens, chemical reactions (pump-probe), small or dilute specimens, and molecular matrices. A SR–FTIR is especially likely to give results that have greater precision than traditional FTIR for submonolayers, polymers, semiconductors, superconductors, and environmental samples. Increasingly, the SR–FTIR is used by forensics researchers to examine potential evidentiary materials, such as drugs, paints, fibers, explosives, polymers, inks, documents, blood, and soil.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A synchrotron-enhanced Fourier transform infrared (SR–FTIR) specializes in combining the tremendous power, brightness, intensity, focusability, and tunability of the photons radiated by a synchrotron with FTIR ability to research the vibrational properties of the lighter elements (i.e., C, N, O, etc.). Infrared (IR) wavelengths correspond to the sizes of molecular bonds having these lighter elements, and only species for which IR photons alter the molecule's dipole moment are detectable and considered to be IR responsive. SR–FTIR excels over traditional FTIR at examining the detailed properties of IR-responsive molecules. Further, SR–FTIR has superior signal-to-noise ratios, brightness, and ability to conduct long-duration scans without altering sample properties. A SR–FTIR scan can reveal exacting molecular details, unrivaled by traditional FTIR. IR-responsive species best analyzed by SR–FTIR can include trace elements, chemical structures, biological specimens, chemical reactions (pump-probe), small or dilute specimens, and molecular matrices. A SR–FTIR is especially likely to give results that have greater precision than traditional FTIR for submonolayers, polymers, semiconductors, superconductors, and environmental samples. Increasingly, the SR–FTIR is used by forensics researchers to examine potential evidentiary materials, such as drugs, paints, fibers, explosives, polymers, inks, documents, blood, and soil.

Key concepts: Fourier transform infrared spectroscopy, Synchrotron, Infrared, Fourier transform, Materials science, Molecule, Analytical Chemistry (journal), Polymer

Related papers

Back to paper searchBrowse research topicsOriginal source
Understanding Why Researchers Should Use Synchrotron-Enhanced FTIR Instead of Traditional FTIR — Research Paper | ScholarLens