Temperature Corrections for the VIZ and Vaisala Radiosondes

James K. Luers, Robert E. Eskridge

Open full text 76 citations

Abstract

The National Weather Service VIZ radiosonde and the Vaisala RS-80 radiosondes are used worldwide to obtain upper-air measurements of atmospheric temperature and moisture. The temperature measured by each sensor is not equal to the atmospheric temperature due to solar and infrared irradiation of the sensor, heat conduction to the sensor from its attachment points, and radiation emitted by the sensor. Presently, only the RS-80 radiosonde applies corrections to the sensor temperature to compensate for these heating sources, and this correction is only considered to be a function of solar angle and pressure. Temperature correction models VIZCOR (VIZ sonde) and VAICOR (Vaisala RS-80 sonde) have been developed that derive the atmospheric temperature from the sensor temperature, taking into account all significant environmental processes that influence the beat transfer to the sensor. These models have been validated by comparing their corrected profiles with atmospheric temperature profiles derived from the NASA multithermistor radiosonde. All three radiosondes were flown on the same balloon during the potential reference radiosonde intercomparison. Excellent agreement has been found between all profiles up to an altitude of 30 km. Since the significant error sources in the VIZCOR, VAICOR, and multithermistor techniques are largely independent, agreement between all profiles implies that the corrected sensor profiles are providing an unbiased estimate of the true atmospheric temperature.

Open-access reader

About this research paper

What this paper is about

The National Weather Service VIZ radiosonde and the Vaisala RS-80 radiosondes are used worldwide to obtain upper-air measurements of atmospheric temperature and moisture. The temperature measured by each sensor is not equal to the atmospheric temperature due to solar and infrared irradiation of the sensor, heat conduction to the sensor from its attachment points, and radiation emitted by the sensor. Presently, only the RS-80 radiosonde applies corrections to the sensor temperature to compensate for these heating sources, and this correction is only considered to be a function of solar angle and pressure. Temperature correction models VIZCOR (VIZ sonde) and VAICOR (Vaisala RS-80 sonde) have been developed that derive the atmospheric temperature from the sensor temperature, taking into account all significant environmental processes that influence the beat transfer to the sensor. These models have been validated by comparing their corrected profiles with atmospheric temperature profiles derived from the NASA multithermistor radiosonde. All three radiosondes were flown on the same balloon during the potential reference radiosonde intercomparison. Excellent agreement has been found between all profiles up to an altitude of 30 km. Since the significant error sources in the VIZCOR, VAICOR, and multithermistor techniques are largely independent, agreement between all profiles implies that the corrected sensor profiles are providing an unbiased estimate of the true atmospheric temperature.

Why it matters

OpenAlex reports 76 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The National Weather Service VIZ radiosonde and the Vaisala RS-80 radiosondes are used worldwide to obtain upper-air measurements of atmospheric temperature and moisture. The temperature measured by each sensor is not equal to the atmospheric temperature due to solar and infrared irradiation of the sensor, heat conduction to the sensor from its attachment points, and radiation emitted by the sensor. Presently, only the RS-80 radiosonde applies corrections to the sensor temperature to compensate for these heating sources, and this correction is only considered to be a function of solar angle and pressure. Temperature correction models VIZCOR (VIZ sonde) and VAICOR (Vaisala RS-80 sonde) have been developed that derive the atmospheric temperature from the sensor temperature, taking into account all significant environmental processes that influence the beat transfer to the sensor. These models have been validated by comparing their corrected profiles with atmospheric temperature profiles derived from the NASA multithermistor radiosonde. All three radiosondes were flown on the same balloon during the potential reference radiosonde intercomparison. Excellent agreement has been found between all profiles up to an altitude of 30 km. Since the significant error sources in the VIZCOR, VAICOR, and multithermistor techniques are largely independent, agreement between all profiles implies that the corrected sensor profiles are providing an unbiased estimate of the true atmospheric temperature.