1995Fusion TechnologyRequires access

Stripper System Performance in the Replacement Tritium Facility

L. K. Heung

Open publisher page 1 citations

Abstract

In the new Replacement Tritium Facility (RTF) at the Savannah River Site, gloveboxes and stripper systems are used to minimize tritium release to the environment. The RTF was built to handle kilogram levels of tritium. It was started up and has been in operation since January 1994. The glovebox-stripper system has performed well in confining tritium leaks from the process. The tritium level in the gloveboxes has been maintained at below 0.1 Ci/m3 under normal conditions. During a large leak of tritium gas from the process to a glovebox, the tritium concentration in the glovebox shot up to about 4000 Ci/m3. However, there was no significant release of tritium to the environment. The tritium reading in the glovebox decreased to a 10 Ci/m3 level after 6 days of stripping. The performance of the glovebox-stripper system during this tritium leak and the possible factors for the long and slow decay of the tritium concentration in the glovebox are discussed in this paper.

About this research paper

What this paper is about

In the new Replacement Tritium Facility (RTF) at the Savannah River Site, gloveboxes and stripper systems are used to minimize tritium release to the environment. The RTF was built to handle kilogram levels of tritium. It was started up and has been in operation since January 1994. The glovebox-stripper system has performed well in confining tritium leaks from the process. The tritium level in the gloveboxes has been maintained at below 0.1 Ci/m3 under normal conditions. During a large leak of tritium gas from the process to a glovebox, the tritium concentration in the glovebox shot up to about 4000 Ci/m3. However, there was no significant release of tritium to the environment. The tritium reading in the glovebox decreased to a 10 Ci/m3 level after 6 days of stripping. The performance of the glovebox-stripper system during this tritium leak and the possible factors for the long and slow decay of the tritium concentration in the glovebox are discussed in this paper.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In the new Replacement Tritium Facility (RTF) at the Savannah River Site, gloveboxes and stripper systems are used to minimize tritium release to the environment. The RTF was built to handle kilogram levels of tritium. It was started up and has been in operation since January 1994. The glovebox-stripper system has performed well in confining tritium leaks from the process. The tritium level in the gloveboxes has been maintained at below 0.1 Ci/m3 under normal conditions. During a large leak of tritium gas from the process to a glovebox, the tritium concentration in the glovebox shot up to about 4000 Ci/m3. However, there was no significant release of tritium to the environment. The tritium reading in the glovebox decreased to a 10 Ci/m3 level after 6 days of stripping. The performance of the glovebox-stripper system during this tritium leak and the possible factors for the long and slow decay of the tritium concentration in the glovebox are discussed in this paper.

Key concepts: Glovebox, Tritium, Human decontamination, Tritium illumination, Radiochemistry, Environmental science, Nuclear engineering, Waste management

Related papers

Back to paper searchBrowse research topicsOriginal source
Stripper System Performance in the Replacement Tritium Facility — Research Paper | ScholarLens