1984CancerRequires access

Chemosensitivity testing of human solid tumors. A review of 1582 assays with 258 clinical correlations

Carl A. Bertelsen, Vernon K. Sondak, Barry D. Mann, Edward L. Korn, David H. Kern

Open publisher page 128 citations

Abstract

To improve clinical interpretation and use of in vitro clonogenic assay results, the authors reviewed their experience to date with chemosensitivity testing of over 1500 solid tumors. All clonogenic assays were performed using a double-layer-soft-agar system with continuous exposure of cells to one concentration of standard anticancer drugs. Significant growth was defined as greater than or equal to 30 colonies/control plate. Clinical responses were determined according to standard criteria. Data were analyzed using two different criteria of in vitro sensitivity (greater than or equal to 50% and greater than or equal to 75% inhibition of colony formation) and independently for each histologic type of tumor. Overall, 68% of specimens plated produced significant growth in vitro. Cloning ability varied from 57% to 82% depending on tumor histology. The assay was 57% reliable for predicting in vivo sensitivity, and 92% reliable for in vivo resistance. Predictive accuracy for sensitivity varied from 30% to 86%, depending on the tumor histology. Use of greater than or equal to 50% ICF (inhibition of colony formation) as criteria for differentiating sensitivity from resistance proved most reliable, although criteria should be individualized for each tumor type to maximize predictive accuracy.

About this research paper

What this paper is about

To improve clinical interpretation and use of in vitro clonogenic assay results, the authors reviewed their experience to date with chemosensitivity testing of over 1500 solid tumors. All clonogenic assays were performed using a double-layer-soft-agar system with continuous exposure of cells to one concentration of standard anticancer drugs. Significant growth was defined as greater than or equal to 30 colonies/control plate. Clinical responses were determined according to standard criteria. Data were analyzed using two different criteria of in vitro sensitivity (greater than or equal to 50% and greater than or equal to 75% inhibition of colony formation) and independently for each histologic type of tumor. Overall, 68% of specimens plated produced significant growth in vitro. Cloning ability varied from 57% to 82% depending on tumor histology. The assay was 57% reliable for predicting in vivo sensitivity, and 92% reliable for in vivo resistance. Predictive accuracy for sensitivity varied from 30% to 86%, depending on the tumor histology. Use of greater than or equal to 50% ICF (inhibition of colony formation) as criteria for differentiating sensitivity from resistance proved most reliable, although criteria should be individualized for each tumor type to maximize predictive accuracy.

Why it matters

OpenAlex reports 128 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To improve clinical interpretation and use of in vitro clonogenic assay results, the authors reviewed their experience to date with chemosensitivity testing of over 1500 solid tumors. All clonogenic assays were performed using a double-layer-soft-agar system with continuous exposure of cells to one concentration of standard anticancer drugs. Significant growth was defined as greater than or equal to 30 colonies/control plate. Clinical responses were determined according to standard criteria. Data were analyzed using two different criteria of in vitro sensitivity (greater than or equal to 50% and greater than or equal to 75% inhibition of colony formation) and independently for each histologic type of tumor. Overall, 68% of specimens plated produced significant growth in vitro. Cloning ability varied from 57% to 82% depending on tumor histology. The assay was 57% reliable for predicting in vivo sensitivity, and 92% reliable for in vivo resistance. Predictive accuracy for sensitivity varied from 30% to 86%, depending on the tumor histology. Use of greater than or equal to 50% ICF (inhibition of colony formation) as criteria for differentiating sensitivity from resistance proved most reliable, although criteria should be individualized for each tumor type to maximize predictive accuracy.

Key concepts: Clonogenic assay, Chemosensitivity assay, In vivo, Medicine, In vitro, Histology, Cancer, Agar

Related papers

Back to paper searchBrowse research topicsOriginal source
Chemosensitivity testing of human solid tumors. A review of 1582 assays with 258 clinical correlations — Research Paper | ScholarLens