Comparison of monaural (CMR) and binaural (BMLD) masking release
Steven van de Par, Armin Kohlrausch
Abstract
Steven van de Par, Armin Kohlrausch
Abstract
Release of masking for a sinusoidal signal of 5 kHz masked by a 25-Hz-wide noise band centered around 5 kHz was measured. The masking release was provided by a second noise band that was comodulated with the on-frequency masker band. For CMR configurations the second noise band was centered at 3 kHz and presented to the ipsi-lateral or to the contra-lateral ear. For BMLD configurations the second band was centered at 5 kHz and presented to the contra-lateral ear. In another condition the second noise band also contained the signal presented with such a phase that maximal differences in the envelope resulted. For both the CMR and the BMLD paradigm, the masking release for the latter condition was larger than for the former condition. To assess further the similarity between monaural and binaural masking release, a sinusoidal masker and either a noise or a sinusoidal signal were used. The data indicate that, at high frequencies, envelope correlation may be a valuable cue for CMR as well as for the BMLD.
OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Release of masking for a sinusoidal signal of 5 kHz masked by a 25-Hz-wide noise band centered around 5 kHz was measured. The masking release was provided by a second noise band that was comodulated with the on-frequency masker band. For CMR configurations the second noise band was centered at 3 kHz and presented to the ipsi-lateral or to the contra-lateral ear. For BMLD configurations the second band was centered at 5 kHz and presented to the contra-lateral ear. In another condition the second noise band also contained the signal presented with such a phase that maximal differences in the envelope resulted. For both the CMR and the BMLD paradigm, the masking release for the latter condition was larger than for the former condition. To assess further the similarity between monaural and binaural masking release, a sinusoidal masker and either a noise or a sinusoidal signal were used. The data indicate that, at high frequencies, envelope correlation may be a valuable cue for CMR as well as for the BMLD.
Key concepts: Monaural, Masking (illustration), Acoustics, Binaural recording, Noise (video), SIGNAL (programming language), Envelope (radar), Critical band