Validation of the Analytical Method for the Determination of Flavonoids in Broccoli
Magdalena Tuszyńska
Abstract
Open-access reader
Magdalena Tuszyńska
Abstract
Open-access reader
Abstract A simple, accurate and selective HPLC method was developed and validated for determination of quercetin and kaempferol, which are the main flavonols in broccoli. The separation was achieved on a reversed-phase C18 column using a mobile phase composed of methanol/water (60/40) and phosphoric acid 0.2% at a flow rate of 1.0 ml min -1 . The detection was carried out on a DAD detector at 370 nm. This method was validated according to the requirements for new methods, which include selectivity, linearity, precision, accuracy, limit of detection and limit of quantitation. The current method demonstrates good linearity, with R 2 > 0.99. The recovery is within 98.07-102.15% and 97.92-101.83% for quercetin and kaempferol, respectively. The method is selective, in that quercetin and kaempferol are well separated from other compounds of broccoli with good resolution. The low limit of detection and limit of quantitation of quercetin and kaempferol enable the detection and quantitation of these flavonoids in broccoli at low con–centrations.
OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Abstract A simple, accurate and selective HPLC method was developed and validated for determination of quercetin and kaempferol, which are the main flavonols in broccoli. The separation was achieved on a reversed-phase C18 column using a mobile phase composed of methanol/water (60/40) and phosphoric acid 0.2% at a flow rate of 1.0 ml min -1 . The detection was carried out on a DAD detector at 370 nm. This method was validated according to the requirements for new methods, which include selectivity, linearity, precision, accuracy, limit of detection and limit of quantitation. The current method demonstrates good linearity, with R 2 > 0.99. The recovery is within 98.07-102.15% and 97.92-101.83% for quercetin and kaempferol, respectively. The method is selective, in that quercetin and kaempferol are well separated from other compounds of broccoli with good resolution. The low limit of detection and limit of quantitation of quercetin and kaempferol enable the detection and quantitation of these flavonoids in broccoli at low con–centrations.
Key concepts: Kaempferol, Detection limit, Chromatography, Quercetin, Chemistry, Flavonols, Phosphoric acid, Biochemistry