2013•Applied OpticsRequires access

Design of imaging keratometer with annular object and charge-coupled device detector

Yuanqing He, Yan Wang, Zhaoqi Wang, Yao Wang, Yongji Liu, Lin Zhang, Yi Zhai, Shengjiang Chang

Open publisher page 2 citations

Abstract

A novel imaging keratometer by the aid of modern optoelectronic technology is proposed. The optical system consists of an annular object, a first imaging subsystem, a second imaging subsystem, and a CCD detector. The measurement range of corneal refraction is from 30D to 60D (5.5-11 mm in radius of curvature), and the accuracy reaches 0.156D, 0.072D, and 0.036D, respectively, for the corneal surface of the steepest, the radius of curvature of 7.8 mm, and the corneal surface of the flattest. The accuracy of corneal astigmatism is verified to be 0.05D for cylindrical refraction of 0.75D. Compared with the traditional keratometer, the proposed keratometer possesses advantages of high accuracy.

About this research paper

What this paper is about

A novel imaging keratometer by the aid of modern optoelectronic technology is proposed. The optical system consists of an annular object, a first imaging subsystem, a second imaging subsystem, and a CCD detector. The measurement range of corneal refraction is from 30D to 60D (5.5-11 mm in radius of curvature), and the accuracy reaches 0.156D, 0.072D, and 0.036D, respectively, for the corneal surface of the steepest, the radius of curvature of 7.8 mm, and the corneal surface of the flattest. The accuracy of corneal astigmatism is verified to be 0.05D for cylindrical refraction of 0.75D. Compared with the traditional keratometer, the proposed keratometer possesses advantages of high accuracy.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A novel imaging keratometer by the aid of modern optoelectronic technology is proposed. The optical system consists of an annular object, a first imaging subsystem, a second imaging subsystem, and a CCD detector. The measurement range of corneal refraction is from 30D to 60D (5.5-11 mm in radius of curvature), and the accuracy reaches 0.156D, 0.072D, and 0.036D, respectively, for the corneal surface of the steepest, the radius of curvature of 7.8 mm, and the corneal surface of the flattest. The accuracy of corneal astigmatism is verified to be 0.05D for cylindrical refraction of 0.75D. Compared with the traditional keratometer, the proposed keratometer possesses advantages of high accuracy.

Key concepts: Keratometer, Optics, Radius of curvature, Detector, Refraction, Curvature, RADIUS, Physics

Related papers

Back to paper searchBrowse research topicsOriginal source
Design of imaging keratometer with annular object and charge-coupled device detector — Research Paper | ScholarLens