2012•IEEE Transactions on Nuclear ScienceRequires access

Fast CdTe and CdZnTe Semiconductor Detector Arrays for Spectroscopic X-Ray Imaging

Andrea Brambilla, Patrice Ouvrier-Buffet, Georges Gonon, Jean Rinkel, Vincent Moulin, Caroline Boudou, L. Verger

Open publisher page 50 citations

Abstract

A growing interest has recently been observed in high flux X-ray imaging detectors with energy discrimination or spectroscopy capabilities. In this study we evaluate the performances of energy sensitive CdTe and CdZnTe detectors for X-ray imaging at fluxes of up to 2 107X/mm2/s in the 20-150 keV energy range. Linear array detectors made from 3 mm thick single CdTe or CdZnTe crystals have 16 pixels with an 800 in pitch. These detectors were coupled to an innovative custom-designed 16-channel fast spectroscopy front-end electronic circuit. For each channel, the signal is continuously digitized and a FPGA controls acquisition and reconstructs the energy spectra on 256 bins for each channel. The detector was tested under X-rays for fluxes in the 105to 2 × 107X/mm2/s range. The main problem encountered at such high fluxes is the multiplication of pile-up events that reduces count rate and degrades energy resolution. When a very short shaping time was used, dead time was lower than 50 ns, and an energy resolution of 11 keV full width at half maximum (FWHM) at 2 × 106X/mm2s and 20 keV (FWHM) at 107X/mm2/ s was achieved. We also show imaging results that illustrate the interest of the spectral information provided by each pixel.

About this research paper

What this paper is about

A growing interest has recently been observed in high flux X-ray imaging detectors with energy discrimination or spectroscopy capabilities. In this study we evaluate the performances of energy sensitive CdTe and CdZnTe detectors for X-ray imaging at fluxes of up to 2 107X/mm2/s in the 20-150 keV energy range. Linear array detectors made from 3 mm thick single CdTe or CdZnTe crystals have 16 pixels with an 800 in pitch. These detectors were coupled to an innovative custom-designed 16-channel fast spectroscopy front-end electronic circuit. For each channel, the signal is continuously digitized and a FPGA controls acquisition and reconstructs the energy spectra on 256 bins for each channel. The detector was tested under X-rays for fluxes in the 105to 2 × 107X/mm2/s range. The main problem encountered at such high fluxes is the multiplication of pile-up events that reduces count rate and degrades energy resolution. When a very short shaping time was used, dead time was lower than 50 ns, and an energy resolution of 11 keV full width at half maximum (FWHM) at 2 × 106X/mm2s and 20 keV (FWHM) at 107X/mm2/ s was achieved. We also show imaging results that illustrate the interest of the spectral information provided by each pixel.

Why it matters

OpenAlex reports 50 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A growing interest has recently been observed in high flux X-ray imaging detectors with energy discrimination or spectroscopy capabilities. In this study we evaluate the performances of energy sensitive CdTe and CdZnTe detectors for X-ray imaging at fluxes of up to 2 107X/mm2/s in the 20-150 keV energy range. Linear array detectors made from 3 mm thick single CdTe or CdZnTe crystals have 16 pixels with an 800 in pitch. These detectors were coupled to an innovative custom-designed 16-channel fast spectroscopy front-end electronic circuit. For each channel, the signal is continuously digitized and a FPGA controls acquisition and reconstructs the energy spectra on 256 bins for each channel. The detector was tested under X-rays for fluxes in the 105to 2 × 107X/mm2/s range. The main problem encountered at such high fluxes is the multiplication of pile-up events that reduces count rate and degrades energy resolution. When a very short shaping time was used, dead time was lower than 50 ns, and an energy resolution of 11 keV full width at half maximum (FWHM) at 2 × 106X/mm2s and 20 keV (FWHM) at 107X/mm2/ s was achieved. We also show imaging results that illustrate the interest of the spectral information provided by each pixel.

Key concepts: Detector, Physics, X-ray detector, Energy (signal processing), Semiconductor detector, Spectroscopy, Optics, Quantum mechanics