Motor Unit Analysis

William S. Pease, Brian L. Bowyer

Open publisher page 27 citations

Abstract

Motor unit action potential (MUAP) measurement parameters are reported to be affected by the type of needle electrode. MUAP amplitude measured with monopolar electrodes has been reported to be up to twice the amplitude recorded with concentric electrodes. We hypothesized that with current technology the difference in recordings from the two needles should be minimal and of little clinical significance. The right extensor digitorum communis muscle was examined in 15 healthy volunteers with first a concentric and then a monopolar needle. The filter band-pass of the electromyograph was 20 Hz to 10 kHz. Four first-recruited MUAPs were isolated by using each electrode. A separate muscle insertion was performed to locate each potential. Amplitudes were maximized. Consecutive MUAPs were averaged and measured. The mean (+/- SD) values of the measurements were as follows: amplitude: monopolar, 1038 (+/- 369) microV; concentric, 912 (+/- 315) microV; duration: monopolar, 10.8 (+/- 2.0) ms; concentric, 9.7 (+/- 1.7) ms. No statistically or clinically significant differences exist between these measurement values.

About this research paper

What this paper is about

Motor unit action potential (MUAP) measurement parameters are reported to be affected by the type of needle electrode. MUAP amplitude measured with monopolar electrodes has been reported to be up to twice the amplitude recorded with concentric electrodes. We hypothesized that with current technology the difference in recordings from the two needles should be minimal and of little clinical significance. The right extensor digitorum communis muscle was examined in 15 healthy volunteers with first a concentric and then a monopolar needle. The filter band-pass of the electromyograph was 20 Hz to 10 kHz. Four first-recruited MUAPs were isolated by using each electrode. A separate muscle insertion was performed to locate each potential. Amplitudes were maximized. Consecutive MUAPs were averaged and measured. The mean (+/- SD) values of the measurements were as follows: amplitude: monopolar, 1038 (+/- 369) microV; concentric, 912 (+/- 315) microV; duration: monopolar, 10.8 (+/- 2.0) ms; concentric, 9.7 (+/- 1.7) ms. No statistically or clinically significant differences exist between these measurement values.

Why it matters

OpenAlex reports 27 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Motor unit action potential (MUAP) measurement parameters are reported to be affected by the type of needle electrode. MUAP amplitude measured with monopolar electrodes has been reported to be up to twice the amplitude recorded with concentric electrodes. We hypothesized that with current technology the difference in recordings from the two needles should be minimal and of little clinical significance. The right extensor digitorum communis muscle was examined in 15 healthy volunteers with first a concentric and then a monopolar needle. The filter band-pass of the electromyograph was 20 Hz to 10 kHz. Four first-recruited MUAPs were isolated by using each electrode. A separate muscle insertion was performed to locate each potential. Amplitudes were maximized. Consecutive MUAPs were averaged and measured. The mean (+/- SD) values of the measurements were as follows: amplitude: monopolar, 1038 (+/- 369) microV; concentric, 912 (+/- 315) microV; duration: monopolar, 10.8 (+/- 2.0) ms; concentric, 9.7 (+/- 1.7) ms. No statistically or clinically significant differences exist between these measurement values.

Key concepts: Concentric, Motor unit, Medicine, Electromyography, Extensor Digitorum Communis, Biomedical engineering, Electrodiagnosis, Amplitude

Related papers

Back to paper searchBrowse research topicsOriginal source
Motor Unit Analysis — Research Paper | ScholarLens