2013Journal of Medical Engineering & TechnologyRequires access

MR-based measurement of spinal cord motion during flexion of the spine: implications for intradural spinal cord stimulator systems

Stephanus Viljoen, C. A. Smittkamp, Brian Dalm, S. Wilson, Chandan G. Reddy, G. T. Gillies, Matthew A. Howard

Open publisher page 14 citations

Abstract

This study develops a means of delivering electrical stimuli directly to the pial surface of the spinal cord for treatment of intractable pain. This intradural implant must remain in direct contact with the cord as it moves within the spinal canal. Therefore, magnetic resonance imaging was used to measure the movement of the spinal cord between neutral and flexed-back positions in a series of volunteers (n = 16). Following flexion of the back, the mean change in the pedicle-to-spinal cord dorsal root entry zone distance at the T10-11 level was (8.5 ± 6.0) mm, i.e. a 71% variation in the range of rostral-caudal movement of the spinal cord across all patients. There will be a large spectrum of spinal cord strains associated with this observed range of rostral-caudal motions, thus calling for suitable axial compliance within the electrode bearing portion of the intradural implant.

About this research paper

What this paper is about

This study develops a means of delivering electrical stimuli directly to the pial surface of the spinal cord for treatment of intractable pain. This intradural implant must remain in direct contact with the cord as it moves within the spinal canal. Therefore, magnetic resonance imaging was used to measure the movement of the spinal cord between neutral and flexed-back positions in a series of volunteers (n = 16). Following flexion of the back, the mean change in the pedicle-to-spinal cord dorsal root entry zone distance at the T10-11 level was (8.5 ± 6.0) mm, i.e. a 71% variation in the range of rostral-caudal movement of the spinal cord across all patients. There will be a large spectrum of spinal cord strains associated with this observed range of rostral-caudal motions, thus calling for suitable axial compliance within the electrode bearing portion of the intradural implant.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study develops a means of delivering electrical stimuli directly to the pial surface of the spinal cord for treatment of intractable pain. This intradural implant must remain in direct contact with the cord as it moves within the spinal canal. Therefore, magnetic resonance imaging was used to measure the movement of the spinal cord between neutral and flexed-back positions in a series of volunteers (n = 16). Following flexion of the back, the mean change in the pedicle-to-spinal cord dorsal root entry zone distance at the T10-11 level was (8.5 ± 6.0) mm, i.e. a 71% variation in the range of rostral-caudal movement of the spinal cord across all patients. There will be a large spectrum of spinal cord strains associated with this observed range of rostral-caudal motions, thus calling for suitable axial compliance within the electrode bearing portion of the intradural implant.

Key concepts: Spinal cord, Spinal cord stimulator, Medicine, Anatomy, Cord, Implant, Magnetic resonance imaging, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
MR-based measurement of spinal cord motion during flexion of the spine: implications for intradural spinal cord stimulator systems — Research Paper | ScholarLens