1992Annals of Plastic SurgeryRequires access

Early Tissue Reaction to Textured Breast Implant Surfaces

Robert M. Brohim, Pamela A. Foresman, Paul K. Hildebrandt, George T. Rodeheaver

Open publisher page 102 citations

Abstract

Capsular contracture around breast implants with smooth surfaces continues to be an unpredictable complication. Some surgeons believe that silicone implants covered with porous polyurethane foam have a lowered potential to contract. These textured implants are not as biocompatible as silicone. Recently, silicone implants with textured surfaces have been introduced with the hope that the incidence of unacceptable implant contracture will be reduced. Using a rat implant model, the tissue reaction to textured implant surfaces was assessed. The implant surfaces evaluated were Silastic II, Siltex, MISTI, Biocell, Silastic MSI, and Même. Disks of each implant material were implanted under the dorsal skin of rats for a period of 28 days. Each implant with its surrounding tissue was excised, processed for histological analysis, and assessed for the tissue's response to the implant with particular emphasis on the formation of a continuous collagen capsule. The results indicated that the magnitude of surface texturing influenced the development of a complete capsule. Implant surfaces with a texture of less than 150 microns in height or depth (Silastic II, Siltex, and MISTI) resulted in the formation of complete capsules. An implant (Biocell) with irregular texturing (200-350 microns) produced an organized capsule over most of its surface with localized interruptions of the capsule at the sites of its deepest cavities. Implant surfaces with texturing that exceeded 350 microns in height or depth (Silastic MSI and Même) resulted in inhibition of the formation of a continuous capsule during this 28-day study.

About this research paper

What this paper is about

Capsular contracture around breast implants with smooth surfaces continues to be an unpredictable complication. Some surgeons believe that silicone implants covered with porous polyurethane foam have a lowered potential to contract. These textured implants are not as biocompatible as silicone. Recently, silicone implants with textured surfaces have been introduced with the hope that the incidence of unacceptable implant contracture will be reduced. Using a rat implant model, the tissue reaction to textured implant surfaces was assessed. The implant surfaces evaluated were Silastic II, Siltex, MISTI, Biocell, Silastic MSI, and Même. Disks of each implant material were implanted under the dorsal skin of rats for a period of 28 days. Each implant with its surrounding tissue was excised, processed for histological analysis, and assessed for the tissue's response to the implant with particular emphasis on the formation of a continuous collagen capsule. The results indicated that the magnitude of surface texturing influenced the development of a complete capsule. Implant surfaces with a texture of less than 150 microns in height or depth (Silastic II, Siltex, and MISTI) resulted in the formation of complete capsules. An implant (Biocell) with irregular texturing (200-350 microns) produced an organized capsule over most of its surface with localized interruptions of the capsule at the sites of its deepest cavities. Implant surfaces with texturing that exceeded 350 microns in height or depth (Silastic MSI and Même) resulted in inhibition of the formation of a continuous capsule during this 28-day study.

Why it matters

OpenAlex reports 102 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Capsular contracture around breast implants with smooth surfaces continues to be an unpredictable complication. Some surgeons believe that silicone implants covered with porous polyurethane foam have a lowered potential to contract. These textured implants are not as biocompatible as silicone. Recently, silicone implants with textured surfaces have been introduced with the hope that the incidence of unacceptable implant contracture will be reduced. Using a rat implant model, the tissue reaction to textured implant surfaces was assessed. The implant surfaces evaluated were Silastic II, Siltex, MISTI, Biocell, Silastic MSI, and Même. Disks of each implant material were implanted under the dorsal skin of rats for a period of 28 days. Each implant with its surrounding tissue was excised, processed for histological analysis, and assessed for the tissue's response to the implant with particular emphasis on the formation of a continuous collagen capsule. The results indicated that the magnitude of surface texturing influenced the development of a complete capsule. Implant surfaces with a texture of less than 150 microns in height or depth (Silastic II, Siltex, and MISTI) resulted in the formation of complete capsules. An implant (Biocell) with irregular texturing (200-350 microns) produced an organized capsule over most of its surface with localized interruptions of the capsule at the sites of its deepest cavities. Implant surfaces with texturing that exceeded 350 microns in height or depth (Silastic MSI and Même) resulted in inhibition of the formation of a continuous capsule during this 28-day study.

Key concepts: Silastic, Implant, Capsular contracture, Silicone, Capsule, Medicine, Breast implant, Biomedical engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Early Tissue Reaction to Textured Breast Implant Surfaces — Research Paper | ScholarLens