2011Unpublished venueRequires access

Failure process of solder joint under mechanical vibration based on a real-time data acquisition method

Hongwu Zhang, Fenglian Sun, Yang Liu, Zhen Zhou, Yong Qin

Open publisher page 3 citations

Abstract

Dynamic voltage signal across solder joints during mechanical vibration test was monitored and collected real-timely with a self-designed data acquisition system. Failure process of solder joint was studied by processing and analyzing data. In the paper, lifetime of solder joint was also compared by changing solder joint location, solder joint composition and vibration acceleration. Results indicated that voltage across solder joints kept at about 0.14v from 0s to 40s, which indicated that crack of solder joint did not form. Voltage of solder joint suddenly rose to 0.45v between 44.2s and 45.2s, which illustrated crack initiation and growth rapidly. In addition, lifetime of solder joint on the edge of test board was about 4.5 times longer than that of solder joint in the center of test board. It was found that with vibration acceleration from 20g to 25g increase of 25%, lifetime of solder joint decreased from 980s to 105s with 89%.

About this research paper

What this paper is about

Dynamic voltage signal across solder joints during mechanical vibration test was monitored and collected real-timely with a self-designed data acquisition system. Failure process of solder joint was studied by processing and analyzing data. In the paper, lifetime of solder joint was also compared by changing solder joint location, solder joint composition and vibration acceleration. Results indicated that voltage across solder joints kept at about 0.14v from 0s to 40s, which indicated that crack of solder joint did not form. Voltage of solder joint suddenly rose to 0.45v between 44.2s and 45.2s, which illustrated crack initiation and growth rapidly. In addition, lifetime of solder joint on the edge of test board was about 4.5 times longer than that of solder joint in the center of test board. It was found that with vibration acceleration from 20g to 25g increase of 25%, lifetime of solder joint decreased from 980s to 105s with 89%.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Dynamic voltage signal across solder joints during mechanical vibration test was monitored and collected real-timely with a self-designed data acquisition system. Failure process of solder joint was studied by processing and analyzing data. In the paper, lifetime of solder joint was also compared by changing solder joint location, solder joint composition and vibration acceleration. Results indicated that voltage across solder joints kept at about 0.14v from 0s to 40s, which indicated that crack of solder joint did not form. Voltage of solder joint suddenly rose to 0.45v between 44.2s and 45.2s, which illustrated crack initiation and growth rapidly. In addition, lifetime of solder joint on the edge of test board was about 4.5 times longer than that of solder joint in the center of test board. It was found that with vibration acceleration from 20g to 25g increase of 25%, lifetime of solder joint decreased from 980s to 105s with 89%.

Key concepts: Soldering, Joint (building), Materials science, Vibration, Acceleration, Structural engineering, Composite material, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Failure process of solder joint under mechanical vibration based on a real-time data acquisition method — Research Paper | ScholarLens