2007AnesthesiologyOpen access

A Randomized Trial of Ultrasound Image–based Skin Surface Marking versus Real-time Ultrasound-guided Internal Jugular Vein Catheterization in Infants

Koji Hosokawa, Nobuaki Shime, Yuko Kato, Satoru Hashimoto

Open full text 110 citations

Abstract

BACKGROUND: Ultrasound-guided central venous catheterization has been recommended to increase the procedural success rate and enhance patient safety. However, few studies have examined the potential advantages of one ultrasound technique with another, specifically in small infants. METHODS: The authors randomly assigned 60 neonates and infants weighing less than 7.5 kg to an ultrasound-guided skin-marking method (n = 27) versus real-time ultrasound-assisted internal jugular venous catheterization (n = 33). The times to successful puncture of the internal jugular vein and to catheterization were measured. Attempts at needle punctures for successful catheterization were counted. Procedural complications were recorded. RESULTS: In the real-time group, compared with the skin- marking group, venous puncture was completed faster (P = 0.03), the time required to catheterize was shorter (P < 0.01), and fewer needle passes were needed. Specifically, fewer than three attempts at puncture were made in 100% of patients in the real-time group, versus 74% of patients in the skin-marking group (P < 0.01). A hematoma and an arterial puncture occurred in one patient each in the skin-marking group. CONCLUSIONS: The real-time ultrasound guidance method could enhance procedural efficacy and safety of internal jugular catheterization in neonates and infants.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: Ultrasound-guided central venous catheterization has been recommended to increase the procedural success rate and enhance patient safety. However, few studies have examined the potential advantages of one ultrasound technique with another, specifically in small infants. METHODS: The authors randomly assigned 60 neonates and infants weighing less than 7.5 kg to an ultrasound-guided skin-marking method (n = 27) versus real-time ultrasound-assisted internal jugular venous catheterization (n = 33). The times to successful puncture of the internal jugular vein and to catheterization were measured. Attempts at needle punctures for successful catheterization were counted. Procedural complications were recorded. RESULTS: In the real-time group, compared with the skin- marking group, venous puncture was completed faster (P = 0.03), the time required to catheterize was shorter (P < 0.01), and fewer needle passes were needed. Specifically, fewer than three attempts at puncture were made in 100% of patients in the real-time group, versus 74% of patients in the skin-marking group (P < 0.01). A hematoma and an arterial puncture occurred in one patient each in the skin-marking group. CONCLUSIONS: The real-time ultrasound guidance method could enhance procedural efficacy and safety of internal jugular catheterization in neonates and infants.

Why it matters

OpenAlex reports 110 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Ultrasound-guided central venous catheterization has been recommended to increase the procedural success rate and enhance patient safety. However, few studies have examined the potential advantages of one ultrasound technique with another, specifically in small infants. METHODS: The authors randomly assigned 60 neonates and infants weighing less than 7.5 kg to an ultrasound-guided skin-marking method (n = 27) versus real-time ultrasound-assisted internal jugular venous catheterization (n = 33). The times to successful puncture of the internal jugular vein and to catheterization were measured. Attempts at needle punctures for successful catheterization were counted. Procedural complications were recorded. RESULTS: In the real-time group, compared with the skin- marking group, venous puncture was completed faster (P = 0.03), the time required to catheterize was shorter (P < 0.01), and fewer needle passes were needed. Specifically, fewer than three attempts at puncture were made in 100% of patients in the real-time group, versus 74% of patients in the skin-marking group (P < 0.01). A hematoma and an arterial puncture occurred in one patient each in the skin-marking group. CONCLUSIONS: The real-time ultrasound guidance method could enhance procedural efficacy and safety of internal jugular catheterization in neonates and infants.

Key concepts: Medicine, Internal jugular vein, Ultrasound, Hematoma, Surgery, Randomized controlled trial, Anesthesia, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
A Randomized Trial of Ultrasound Image–based Skin Surface Marking versus Real-time Ultrasound-guided Internal Jugular Vein Catheterization in Infants — Research Paper | ScholarLens