Facility for simulating PWR transients for testing pressurizer safety valves
S.E. Weismantel, G. Kanupka
Abstract
S.E. Weismantel, G. Kanupka
Abstract
The design of Pressurized Water Reactors (PWRs) incorporates ASME Code safety valves in order to prevent overpressurization of the primary coolant system. This paper describes a facility that was built to test full scale safety valves. The types of PWR transients simulated and the various modes of facility operation are described. Also presented are typical test results that demonstrate the success achieved in simulating the desired transients.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The design of Pressurized Water Reactors (PWRs) incorporates ASME Code safety valves in order to prevent overpressurization of the primary coolant system. This paper describes a facility that was built to test full scale safety valves. The types of PWR transients simulated and the various modes of facility operation are described. Also presented are typical test results that demonstrate the success achieved in simulating the desired transients.
Key concepts: Pressurizer, Safety valve, Pressurized water reactor, Coolant, Nuclear engineering, Engineering, Relief valve, Mechanical engineering