2010Journal of Separation ScienceRequires access

Single‐step extraction followed by LC for determination of (fluoro)quinolone drug residues in muscle, eggs, and milk

Hee‐Jung Cho, Hee Yi, Soo Min Cho, Dong Goo Lee, Kyul Cho, A.M. Abd El‐Aty, Jae‐Han Shim, Soonho Lee, Jiyoon Jeong, Ho‐Chul Shin

Open publisher page 36 citations

Abstract

In this study, a simplified method for the extraction and determination of seven fluoroquinolone residues (danofloxacin, difloxacin, enrofloxacin, marbofloxacin, orbifloxacin, ofloxacin, and sarafloxacin) and three quinolones (oxolinic acid, flumequine, and nalidixic acid), in porcine muscle, table eggs, and commercial whole milk, which required no cleanup step, was devised. This procedure involves the extraction of analytes from the samples via liquid-phase extraction, and the subsequent quantitative determination was accomplished via LC-fluorescence detection. Analyte separation was successfully conducted on an XBridge-C(18) column, with a linear gradient mobile phase composed of acetonitrile and 0.01 M oxalic acid buffer at pH=3.5. The one-step liquid-liquid extraction method evidenced good selectivity, precision (RSDs=0.26-15.07%), and recovery of the extractable analytes, ranging from 61.12 to 115.93% in matrices. The LOQs ranged from 0.3 to 25 microg/kg. A survey of ten samples purchased from local markets was conducted, and none of the samples harbored fluoroquinolone residues. This method is an improvement over existing methodologies, since no additional cleanup was necessary.

About this research paper

What this paper is about

In this study, a simplified method for the extraction and determination of seven fluoroquinolone residues (danofloxacin, difloxacin, enrofloxacin, marbofloxacin, orbifloxacin, ofloxacin, and sarafloxacin) and three quinolones (oxolinic acid, flumequine, and nalidixic acid), in porcine muscle, table eggs, and commercial whole milk, which required no cleanup step, was devised. This procedure involves the extraction of analytes from the samples via liquid-phase extraction, and the subsequent quantitative determination was accomplished via LC-fluorescence detection. Analyte separation was successfully conducted on an XBridge-C(18) column, with a linear gradient mobile phase composed of acetonitrile and 0.01 M oxalic acid buffer at pH=3.5. The one-step liquid-liquid extraction method evidenced good selectivity, precision (RSDs=0.26-15.07%), and recovery of the extractable analytes, ranging from 61.12 to 115.93% in matrices. The LOQs ranged from 0.3 to 25 microg/kg. A survey of ten samples purchased from local markets was conducted, and none of the samples harbored fluoroquinolone residues. This method is an improvement over existing methodologies, since no additional cleanup was necessary.

Why it matters

OpenAlex reports 36 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this study, a simplified method for the extraction and determination of seven fluoroquinolone residues (danofloxacin, difloxacin, enrofloxacin, marbofloxacin, orbifloxacin, ofloxacin, and sarafloxacin) and three quinolones (oxolinic acid, flumequine, and nalidixic acid), in porcine muscle, table eggs, and commercial whole milk, which required no cleanup step, was devised. This procedure involves the extraction of analytes from the samples via liquid-phase extraction, and the subsequent quantitative determination was accomplished via LC-fluorescence detection. Analyte separation was successfully conducted on an XBridge-C(18) column, with a linear gradient mobile phase composed of acetonitrile and 0.01 M oxalic acid buffer at pH=3.5. The one-step liquid-liquid extraction method evidenced good selectivity, precision (RSDs=0.26-15.07%), and recovery of the extractable analytes, ranging from 61.12 to 115.93% in matrices. The LOQs ranged from 0.3 to 25 microg/kg. A survey of ten samples purchased from local markets was conducted, and none of the samples harbored fluoroquinolone residues. This method is an improvement over existing methodologies, since no additional cleanup was necessary.

Key concepts: Danofloxacin, Flumequine, Chromatography, Oxolinic acid, Chemistry, Enrofloxacin, Analyte, Extraction (chemistry)

Related papers

Back to paper searchBrowse research topicsOriginal source
Single‐step extraction followed by LC for determination of (fluoro)quinolone drug residues in muscle, eggs, and milk — Research Paper | ScholarLens