Electrophysiological Effects of a New Antiarrhythmic Agent, Flecainide, on the Intact Canine Heart
A B Hodess, William P. Follansbee, Joseph F. Spear, E. Neil Moore
Abstract
A B Hodess, William P. Follansbee, Joseph F. Spear, E. Neil Moore
Abstract
The cardiac electrophysiology of flecainide a new antiarrhythmic agent, was studied in open-chested dogs. At plasma concentrations of 0.4 to 0.7 microgram/ml, flecainide significantly prolonged atrioventricular (AV) conduction. At plasma concentrations greater than 6.5 micrograms/ml, flecainide caused delay throughout the conduction system (77--240%). Low plasma levels of flecainide caused slight prolongation in atrial effective refractory period and AV nodal functional and relative refractory periods. At flecainide levels of 0.7 microgram/ml, ventricular response during atrial fibrillation was significantly slowed. The effects of flecainide on AV nodal and infranodal conduction and refractoriness were significantly enhanced by d,1-propranolol (0.5 mg/kg) but were unaffected by ouabain (0.01 mg/kg). The ventricular fibrillation threshold of supraventricular beats and ventricular premature beats increased with increasing plasma flecainide concentration (122% at 9.3 micrograms/ml and 172% at 1.3 micrograms/ml, respectively). Flecainide slowed ectopic atrial and ventricular pacemakers without affecting sinusor junctional pacemakers.
OpenAlex reports 87 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The cardiac electrophysiology of flecainide a new antiarrhythmic agent, was studied in open-chested dogs. At plasma concentrations of 0.4 to 0.7 microgram/ml, flecainide significantly prolonged atrioventricular (AV) conduction. At plasma concentrations greater than 6.5 micrograms/ml, flecainide caused delay throughout the conduction system (77--240%). Low plasma levels of flecainide caused slight prolongation in atrial effective refractory period and AV nodal functional and relative refractory periods. At flecainide levels of 0.7 microgram/ml, ventricular response during atrial fibrillation was significantly slowed. The effects of flecainide on AV nodal and infranodal conduction and refractoriness were significantly enhanced by d,1-propranolol (0.5 mg/kg) but were unaffected by ouabain (0.01 mg/kg). The ventricular fibrillation threshold of supraventricular beats and ventricular premature beats increased with increasing plasma flecainide concentration (122% at 9.3 micrograms/ml and 172% at 1.3 micrograms/ml, respectively). Flecainide slowed ectopic atrial and ventricular pacemakers without affecting sinusor junctional pacemakers.
Key concepts: Flecainide, Electrophysiology, Medicine, Cardiology, Internal medicine, Pharmacology, Anesthesia, Atrial fibrillation