Background and Objectives. This study was designed to determine the effectiveness of fibrin glue plus conventional drain placement versus conventional drain placement in the prevention of seromas after breast procedures. Among methods employed to reduce seroma magnitude and duration, fibrin glue has been proposed in numerous studies, with controversial results. Design and Setting. A prospective, randomized, controlled study of subjects who were randomized into control and experimental groups was conducted. Methods. Collected data included age, surgeon, medical and surgical history, comorbidities, procedure performed, number of axillary nodes, number of positive axillary nodes collected, final pathologic diagnosis, cancer stage, hospital stay, postoperative day of drain removal, complications, incidence of seroma formation, interval to seroma resolution, and number of postoperative visits. Results. Analysis of 60 patients showed similarly matched groups. Seroma formation rate was 24.1% in the control group and 16.1% in the fibrin glue group. The rate of wound complications was similar. Conclusions. Although use of fibrin sealant resulted in a nonsignificant decrease in seroma formation rate compared with that of drain placement, the higher cost and cumbersome technique tend to indicate that there is no advantage to using fibrin glue over drain placement with the technique described.
OpenAlex reports 27 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Background and Objectives. This study was designed to determine the effectiveness of fibrin glue plus conventional drain placement versus conventional drain placement in the prevention of seromas after breast procedures. Among methods employed to reduce seroma magnitude and duration, fibrin glue has been proposed in numerous studies, with controversial results. Design and Setting. A prospective, randomized, controlled study of subjects who were randomized into control and experimental groups was conducted. Methods. Collected data included age, surgeon, medical and surgical history, comorbidities, procedure performed, number of axillary nodes, number of positive axillary nodes collected, final pathologic diagnosis, cancer stage, hospital stay, postoperative day of drain removal, complications, incidence of seroma formation, interval to seroma resolution, and number of postoperative visits. Results. Analysis of 60 patients showed similarly matched groups. Seroma formation rate was 24.1% in the control group and 16.1% in the fibrin glue group. The rate of wound complications was similar. Conclusions. Although use of fibrin sealant resulted in a nonsignificant decrease in seroma formation rate compared with that of drain placement, the higher cost and cumbersome technique tend to indicate that there is no advantage to using fibrin glue over drain placement with the technique described.
Key concepts: Seroma, Fibrin glue, Medicine, Surgery, GLUE, Fibrin, Fibrin Tissue Adhesive, Randomized controlled trial