2012•Unpublished venueRequires access

The nonlinear dielectric response of water tree degradation in a medium voltage power cable

Noor Hana Hussain, Nursyarizal Mohd Nor, Mohd Faris Abdullah, Khalid Masood Ashraf, Zahoor Ahmed Baloch, Sohrab Khan Bizanjo

Open publisher page 0 citations

Abstract

Medium voltage (MV) cross linked polyethylene (XLPE) insulated power cables are being used in electrical power distribution system networks throughout the world. Deterioration like voids, cracks, delimitation, protrusions and contaminants in the cable insulation may initiate water tree, electrical tree and partial discharge. Water treeing is the main cause of insulation failure in MV power cables. The nonlinear dielectric response of water tree generates harmonics in the AC loss current. This paper presents a detailed study of the characterization of XLPE cable insulation. The morphological study of XLPE cable samples has been carried out by using the Scanning Electron Microscope (SEM) and the chemical analysis has been carried out by using Fourier Transform Infrared spectroscopy (FTIR). The MATLAB/SIMULINK program has been used to model and simulate degradation in the power cable due to water tree. This model is simulated with supply frequencies at 50 Hz, 100 Hz and 150 Hz. The 3rdharmonic current has been recorded from the total current flowing through the cable insulation. The generated harmonics have a good relationship with degradation caused by water tree.

About this research paper

What this paper is about

Medium voltage (MV) cross linked polyethylene (XLPE) insulated power cables are being used in electrical power distribution system networks throughout the world. Deterioration like voids, cracks, delimitation, protrusions and contaminants in the cable insulation may initiate water tree, electrical tree and partial discharge. Water treeing is the main cause of insulation failure in MV power cables. The nonlinear dielectric response of water tree generates harmonics in the AC loss current. This paper presents a detailed study of the characterization of XLPE cable insulation. The morphological study of XLPE cable samples has been carried out by using the Scanning Electron Microscope (SEM) and the chemical analysis has been carried out by using Fourier Transform Infrared spectroscopy (FTIR). The MATLAB/SIMULINK program has been used to model and simulate degradation in the power cable due to water tree. This model is simulated with supply frequencies at 50 Hz, 100 Hz and 150 Hz. The 3rdharmonic current has been recorded from the total current flowing through the cable insulation. The generated harmonics have a good relationship with degradation caused by water tree.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Medium voltage (MV) cross linked polyethylene (XLPE) insulated power cables are being used in electrical power distribution system networks throughout the world. Deterioration like voids, cracks, delimitation, protrusions and contaminants in the cable insulation may initiate water tree, electrical tree and partial discharge. Water treeing is the main cause of insulation failure in MV power cables. The nonlinear dielectric response of water tree generates harmonics in the AC loss current. This paper presents a detailed study of the characterization of XLPE cable insulation. The morphological study of XLPE cable samples has been carried out by using the Scanning Electron Microscope (SEM) and the chemical analysis has been carried out by using Fourier Transform Infrared spectroscopy (FTIR). The MATLAB/SIMULINK program has been used to model and simulate degradation in the power cable due to water tree. This model is simulated with supply frequencies at 50 Hz, 100 Hz and 150 Hz. The 3rdharmonic current has been recorded from the total current flowing through the cable insulation. The generated harmonics have a good relationship with degradation caused by water tree.

Key concepts: Electrical treeing, Power cable, Cross-linked polyethylene, Harmonics, High-voltage cable, Materials science, Partial discharge, Degradation (telecommunications)

Related papers

Back to paper searchBrowse research topicsOriginal source
The nonlinear dielectric response of water tree degradation in a medium voltage power cable — Research Paper | ScholarLens