1987Pacing and Clinical ElectrophysiologyRequires access

Computer Modeling of DDD Pacemakers for Use in Prophylaxis of Junctional Reentry Tachycardia

Marek Malík, D. Wyn Davies, A. John Camm

Open publisher page 13 citations

Abstract

A computer simulation model of cardiac rhythm and heart-pacemaker interactions has been used to examine the response of short AV delay DDD pacing to an atrial premature depolarization in patients with a potential junctional reentry circuit. Special attention was given to the possibility of using the pacemaker to prevent atrioventricular reentry tachycardia mediated by a bidirectional accessory pathway. The computational experiments examined: (a) the differences between pacing modes with constant and quasi-Wenckebach prolongation of AV delay; (b) the effects of imposing the restrictions of a pacemaker atrial refractory period and upper rate limit; and (c) the effects of varying the ventricular refractory period so that it was either the same or longer than that of the atria. The computational results prove that some possible modes of initiation of junctional reentry tachycardia are beyond the prophylactic capabilities of current DDD pacemakers. Future possibilities involving the use of computer modeling to develop more sophisticated pacemaker modes are briefly discussed.

About this research paper

What this paper is about

A computer simulation model of cardiac rhythm and heart-pacemaker interactions has been used to examine the response of short AV delay DDD pacing to an atrial premature depolarization in patients with a potential junctional reentry circuit. Special attention was given to the possibility of using the pacemaker to prevent atrioventricular reentry tachycardia mediated by a bidirectional accessory pathway. The computational experiments examined: (a) the differences between pacing modes with constant and quasi-Wenckebach prolongation of AV delay; (b) the effects of imposing the restrictions of a pacemaker atrial refractory period and upper rate limit; and (c) the effects of varying the ventricular refractory period so that it was either the same or longer than that of the atria. The computational results prove that some possible modes of initiation of junctional reentry tachycardia are beyond the prophylactic capabilities of current DDD pacemakers. Future possibilities involving the use of computer modeling to develop more sophisticated pacemaker modes are briefly discussed.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A computer simulation model of cardiac rhythm and heart-pacemaker interactions has been used to examine the response of short AV delay DDD pacing to an atrial premature depolarization in patients with a potential junctional reentry circuit. Special attention was given to the possibility of using the pacemaker to prevent atrioventricular reentry tachycardia mediated by a bidirectional accessory pathway. The computational experiments examined: (a) the differences between pacing modes with constant and quasi-Wenckebach prolongation of AV delay; (b) the effects of imposing the restrictions of a pacemaker atrial refractory period and upper rate limit; and (c) the effects of varying the ventricular refractory period so that it was either the same or longer than that of the atria. The computational results prove that some possible modes of initiation of junctional reentry tachycardia are beyond the prophylactic capabilities of current DDD pacemakers. Future possibilities involving the use of computer modeling to develop more sophisticated pacemaker modes are briefly discussed.

Key concepts: Reentry, Medicine, Refractory period, Cardiology, Tachycardia, Internal medicine, Effective refractory period, Prolongation

Related papers

Back to paper searchBrowse research topicsOriginal source
Computer Modeling of DDD Pacemakers for Use in Prophylaxis of Junctional Reentry Tachycardia — Research Paper | ScholarLens