2003Journal of Agricultural and Food ChemistryRequires access

Determination of Trace Cadmium in Rice by Flow Injection On-Line Filterless Precipitation−Dissolution Preconcentration Coupled with Flame Atomic Absorption Spectrometry

Qiao-Yun Ye, Yan Li, Yan Jiang, Xiu‐Ping Yan

Open publisher page 40 citations

Abstract

A simple, environmentally friendly, cost-effective, and sensitive method was developed for the determination of trace cadmium in rice by flow injection (FI) on-line precipitation preconcentration coupled with flame atomic absorption spectrometry (FAAS). The precipitation preconcentration of trace cadmium was achieved by on-line merging of the sample and ammonia solutions. The resultant precipitates were on-line collected by a knotted reactor (KR) without filtration. A solution of 1 mol L(-1) HNO(3) was employed to dissolve the collected precipitates and to deliver the analyte into the FAAS system for on-line detection. Preconcentration at a sample loading flow rate of 3.8 mL min(-1) for 35 s gave an enhancement factor of 44 and a detection limit (3sigma) of 0.002 microg g(-1) for the solid sample with a sample throughput of 72 h(-1). The precision (RSD, n = 11) was 2.0% at the 4.0 microg L(-1) level. The concentration of cadmium in a certified reference material (GBW 08511, rice flour) by the developed method using simple aqueous standards for calibration was in good agreement with the certified value. The proposed method was also successfully applied to the determination of trace cadmium in locally collected rice samples.

About this research paper

What this paper is about

A simple, environmentally friendly, cost-effective, and sensitive method was developed for the determination of trace cadmium in rice by flow injection (FI) on-line precipitation preconcentration coupled with flame atomic absorption spectrometry (FAAS). The precipitation preconcentration of trace cadmium was achieved by on-line merging of the sample and ammonia solutions. The resultant precipitates were on-line collected by a knotted reactor (KR) without filtration. A solution of 1 mol L(-1) HNO(3) was employed to dissolve the collected precipitates and to deliver the analyte into the FAAS system for on-line detection. Preconcentration at a sample loading flow rate of 3.8 mL min(-1) for 35 s gave an enhancement factor of 44 and a detection limit (3sigma) of 0.002 microg g(-1) for the solid sample with a sample throughput of 72 h(-1). The precision (RSD, n = 11) was 2.0% at the 4.0 microg L(-1) level. The concentration of cadmium in a certified reference material (GBW 08511, rice flour) by the developed method using simple aqueous standards for calibration was in good agreement with the certified value. The proposed method was also successfully applied to the determination of trace cadmium in locally collected rice samples.

Why it matters

OpenAlex reports 40 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple, environmentally friendly, cost-effective, and sensitive method was developed for the determination of trace cadmium in rice by flow injection (FI) on-line precipitation preconcentration coupled with flame atomic absorption spectrometry (FAAS). The precipitation preconcentration of trace cadmium was achieved by on-line merging of the sample and ammonia solutions. The resultant precipitates were on-line collected by a knotted reactor (KR) without filtration. A solution of 1 mol L(-1) HNO(3) was employed to dissolve the collected precipitates and to deliver the analyte into the FAAS system for on-line detection. Preconcentration at a sample loading flow rate of 3.8 mL min(-1) for 35 s gave an enhancement factor of 44 and a detection limit (3sigma) of 0.002 microg g(-1) for the solid sample with a sample throughput of 72 h(-1). The precision (RSD, n = 11) was 2.0% at the 4.0 microg L(-1) level. The concentration of cadmium in a certified reference material (GBW 08511, rice flour) by the developed method using simple aqueous standards for calibration was in good agreement with the certified value. The proposed method was also successfully applied to the determination of trace cadmium in locally collected rice samples.

Key concepts: Detection limit, Cadmium, Certified reference materials, Chemistry, Atomic absorption spectroscopy, Analytical Chemistry (journal), Dissolution, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Trace Cadmium in Rice by Flow Injection On-Line Filterless Precipitation−Dissolution Preconcentration Coupled with Flame Atomic Absorption Spectrometry — Research Paper | ScholarLens