2014•Unpublished venueRequires access

A low-offset high CMRR current-mode instrumentation amplifier using differential difference current conveyor

Uğur Çini

Open publisher page 7 citations

Abstract

Current-mode circuits are generally desirable for their high bandwidth. Moreover, current-mode instrumentation amplifiers have an advantage over voltage-mode counterparts that, they do not require precise resistor matching for a high CMRR. In this work, a current-mode instrumentation amplifier is proposed by employing Differential Difference Current Conveyor (DDCC). The proposed structure employs a single DDCC element, and an operational amplifier is used as a buffer or a final amplifier stage. After the explanation of the circuit, redundant output feedback (ROFB) circuit is presented to increase CMRR and to overcome the offset voltage at the output of the DDCC. The DDCC element is designed with 0.35μm technology and the proposed circuits are simulated using HSPICE. The proposed circuit with the feedback path provides more than 110 dB CMRR value at 1 MHz which is much higher than other current-mode implementations.

About this research paper

What this paper is about

Current-mode circuits are generally desirable for their high bandwidth. Moreover, current-mode instrumentation amplifiers have an advantage over voltage-mode counterparts that, they do not require precise resistor matching for a high CMRR. In this work, a current-mode instrumentation amplifier is proposed by employing Differential Difference Current Conveyor (DDCC). The proposed structure employs a single DDCC element, and an operational amplifier is used as a buffer or a final amplifier stage. After the explanation of the circuit, redundant output feedback (ROFB) circuit is presented to increase CMRR and to overcome the offset voltage at the output of the DDCC. The DDCC element is designed with 0.35μm technology and the proposed circuits are simulated using HSPICE. The proposed circuit with the feedback path provides more than 110 dB CMRR value at 1 MHz which is much higher than other current-mode implementations.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Current-mode circuits are generally desirable for their high bandwidth. Moreover, current-mode instrumentation amplifiers have an advantage over voltage-mode counterparts that, they do not require precise resistor matching for a high CMRR. In this work, a current-mode instrumentation amplifier is proposed by employing Differential Difference Current Conveyor (DDCC). The proposed structure employs a single DDCC element, and an operational amplifier is used as a buffer or a final amplifier stage. After the explanation of the circuit, redundant output feedback (ROFB) circuit is presented to increase CMRR and to overcome the offset voltage at the output of the DDCC. The DDCC element is designed with 0.35μm technology and the proposed circuits are simulated using HSPICE. The proposed circuit with the feedback path provides more than 110 dB CMRR value at 1 MHz which is much higher than other current-mode implementations.

Key concepts: Current conveyor, Input offset voltage, Instrumentation amplifier, Common-mode rejection ratio, Resistor, Current-feedback operational amplifier, Amplifier, Operational amplifier

Related papers

Back to paper searchBrowse research topicsOriginal source
A low-offset high CMRR current-mode instrumentation amplifier using differential difference current conveyor — Research Paper | ScholarLens