Yeasts are an increasingly common cause of nosocomial bloodstream infections. Methods for their detection are many; controlled comparisons are few. The vented FAN aerobic blood culture medium has been shown to be superior to the standard BacT/ALERT aerobic medium for the detection of fungemia as well as bacteremia. The BACTEC selective fungal medium (FM) (BD Biosciences, Sparks, Md.) allowed detection of more episodes of fungemia than did a resin-containing medium with equal volumes of blood cultured. Therefore, we compared vented FAN to FM for the ability to recover fungi from the blood of patients who were at increased risk of having fungemia. From 5,109 cultures processed for which both FAN and FM bottles were adequately filled, fungi were recovered from 87 cultures. Of these, 47 were detected with both bottles, 12 were detected with FAN only, and 28 were detected with FM only (P < 0.05). FAN was the first bottle positive for 36 of the 47 cultures for which both bottles yielded the same fungus, whereas the FM bottle was the first bottle positive for 11 cultures (P < 0.001). A total of 54 episodes of fungemia were identified, with 40 detected by both media, 4 detected only by FAN, and 10 detected only by FM (P value, not significant). We conclude that the vented FAN aerobic bottle is comparable to the FM bottle for detection of episodes of yeast infection but has the added benefit of detecting bacteria.

About this research paper

What this paper is about

Yeasts are an increasingly common cause of nosocomial bloodstream infections. Methods for their detection are many; controlled comparisons are few. The vented FAN aerobic blood culture medium has been shown to be superior to the standard BacT/ALERT aerobic medium for the detection of fungemia as well as bacteremia. The BACTEC selective fungal medium (FM) (BD Biosciences, Sparks, Md.) allowed detection of more episodes of fungemia than did a resin-containing medium with equal volumes of blood cultured. Therefore, we compared vented FAN to FM for the ability to recover fungi from the blood of patients who were at increased risk of having fungemia. From 5,109 cultures processed for which both FAN and FM bottles were adequately filled, fungi were recovered from 87 cultures. Of these, 47 were detected with both bottles, 12 were detected with FAN only, and 28 were detected with FM only (P < 0.05). FAN was the first bottle positive for 36 of the 47 cultures for which both bottles yielded the same fungus, whereas the FM bottle was the first bottle positive for 11 cultures (P < 0.001). A total of 54 episodes of fungemia were identified, with 40 detected by both media, 4 detected only by FAN, and 10 detected only by FM (P value, not significant). We conclude that the vented FAN aerobic bottle is comparable to the FM bottle for detection of episodes of yeast infection but has the added benefit of detecting bacteria.

Why it matters

OpenAlex reports 53 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Yeasts are an increasingly common cause of nosocomial bloodstream infections. Methods for their detection are many; controlled comparisons are few. The vented FAN aerobic blood culture medium has been shown to be superior to the standard BacT/ALERT aerobic medium for the detection of fungemia as well as bacteremia. The BACTEC selective fungal medium (FM) (BD Biosciences, Sparks, Md.) allowed detection of more episodes of fungemia than did a resin-containing medium with equal volumes of blood cultured. Therefore, we compared vented FAN to FM for the ability to recover fungi from the blood of patients who were at increased risk of having fungemia. From 5,109 cultures processed for which both FAN and FM bottles were adequately filled, fungi were recovered from 87 cultures. Of these, 47 were detected with both bottles, 12 were detected with FAN only, and 28 were detected with FM only (P < 0.05). FAN was the first bottle positive for 36 of the 47 cultures for which both bottles yielded the same fungus, whereas the FM bottle was the first bottle positive for 11 cultures (P < 0.001). A total of 54 episodes of fungemia were identified, with 40 detected by both media, 4 detected only by FAN, and 10 detected only by FM (P value, not significant). We conclude that the vented FAN aerobic bottle is comparable to the FM bottle for detection of episodes of yeast infection but has the added benefit of detecting bacteria.