2010Advances in science and technologyOpen access

Osseointegration of Titanium Alloy Macroporous Implants Obtained by PM with Addition of Gelatin

Tamiye Simone Goia, Kalan Bastos Violin, Marcelo Yoshimoto, José Carlos Bressiani, Ana Helena A. Bressiani

Open full text 14 citations

Abstract

Studies of titanium and its alloys commonly used as biomaterials aim to improve bone-implant interface related problems, which may determine the quality, bone repairing time and therefore the implant clinical success. The goal of this study was to evaluate, in rats, osseointegration of macroporous implants produced by powder metallurgy (PM) method with controlled addition of gelatin. As control group, samples of commercially pure titanium (cpTi) and Ti-13Nb-13Zr alloy obtained by the PM process were used. To obtaining the porous samples, at most 15% in weight of gelatin was added to metallic powders, the samples were thermally treated in vacuum furnace, and sintered at 1150°C. The osseointegration evaluation was performed in Wistar rats, males, for a 28 days period. The morphological analyses, optical microscopy and scanning electron microscopy (SEM), evaluated qualitatively the osseointegration. The PM process modified by addition of gelatin provides with success the obtaining of porous metallic implants. Pore size obtained by this technique allowed the necessary nourishing to cell survival, proving that pores and channels form a high interconnectable network represented by the osseointegration and osteoconduction feature of the porous alloy.

About this research paper

What this paper is about

Studies of titanium and its alloys commonly used as biomaterials aim to improve bone-implant interface related problems, which may determine the quality, bone repairing time and therefore the implant clinical success. The goal of this study was to evaluate, in rats, osseointegration of macroporous implants produced by powder metallurgy (PM) method with controlled addition of gelatin. As control group, samples of commercially pure titanium (cpTi) and Ti-13Nb-13Zr alloy obtained by the PM process were used. To obtaining the porous samples, at most 15% in weight of gelatin was added to metallic powders, the samples were thermally treated in vacuum furnace, and sintered at 1150°C. The osseointegration evaluation was performed in Wistar rats, males, for a 28 days period. The morphological analyses, optical microscopy and scanning electron microscopy (SEM), evaluated qualitatively the osseointegration. The PM process modified by addition of gelatin provides with success the obtaining of porous metallic implants. Pore size obtained by this technique allowed the necessary nourishing to cell survival, proving that pores and channels form a high interconnectable network represented by the osseointegration and osteoconduction feature of the porous alloy.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Studies of titanium and its alloys commonly used as biomaterials aim to improve bone-implant interface related problems, which may determine the quality, bone repairing time and therefore the implant clinical success. The goal of this study was to evaluate, in rats, osseointegration of macroporous implants produced by powder metallurgy (PM) method with controlled addition of gelatin. As control group, samples of commercially pure titanium (cpTi) and Ti-13Nb-13Zr alloy obtained by the PM process were used. To obtaining the porous samples, at most 15% in weight of gelatin was added to metallic powders, the samples were thermally treated in vacuum furnace, and sintered at 1150°C. The osseointegration evaluation was performed in Wistar rats, males, for a 28 days period. The morphological analyses, optical microscopy and scanning electron microscopy (SEM), evaluated qualitatively the osseointegration. The PM process modified by addition of gelatin provides with success the obtaining of porous metallic implants. Pore size obtained by this technique allowed the necessary nourishing to cell survival, proving that pores and channels form a high interconnectable network represented by the osseointegration and osteoconduction feature of the porous alloy.

Key concepts: Osseointegration, Gelatin, Materials science, Titanium, Scanning electron microscope, Titanium alloy, Alloy, Porosity