2012Analytical LettersRequires access

Simultaneous Determination of Gallium(III) and Indium(III) in Urine and Water Samples with Cloud Point Extraction and by Inductively Coupled Plasma Optical Emission Spectrometry

Huiming Liu, Jian-Kai Jiang, Yun-Hua Lin

Open publisher page 22 citations

Abstract

A simple, sensitive, and selective method for the determination of gallium and indium in different samples at trace levels is presented. This method was based on complexation of analyzes with 2-(5-bromo-2- pyridylazo)-5-diethylaminophenol (5-Br-PADAP) in the presence of t-octylphenoxy-polyethoxyethanol (Triton X-100). After phase separation, the analyzed concentrations were determined by inductively coupled plasma optical emission spectrometry. Quantitative extraction of gallium and indium was performed at pH 7.0, 1.7 mmol L−1, 5-Br-PADAP, 1.3% (w/v) Triton X-100 and at 75°C. The relative standard deviations (RSD) of this method were between 0.3% and 1.6% (C = 20 ng mL−1, n = 9). The calibration curve is linear over the concentration range 6–200 ng mL−1 for gallium and 2–200 ng mL−1 for indium, respectively. The limits of detection (LOD) for gallium and indium were 0.72 and 0.28 ng mL−1, respectively. The results showed the developed method was not susceptible to matrix effects, providing recoveries between 98% and 102%. The accuracy of the developed method was evaluated by the analysis of spiked certified reference materials. The developed method was successfully applied to gallium and indium determination in urine and lake water with satisfactory results.

About this research paper

What this paper is about

A simple, sensitive, and selective method for the determination of gallium and indium in different samples at trace levels is presented. This method was based on complexation of analyzes with 2-(5-bromo-2- pyridylazo)-5-diethylaminophenol (5-Br-PADAP) in the presence of t-octylphenoxy-polyethoxyethanol (Triton X-100). After phase separation, the analyzed concentrations were determined by inductively coupled plasma optical emission spectrometry. Quantitative extraction of gallium and indium was performed at pH 7.0, 1.7 mmol L−1, 5-Br-PADAP, 1.3% (w/v) Triton X-100 and at 75°C. The relative standard deviations (RSD) of this method were between 0.3% and 1.6% (C = 20 ng mL−1, n = 9). The calibration curve is linear over the concentration range 6–200 ng mL−1 for gallium and 2–200 ng mL−1 for indium, respectively. The limits of detection (LOD) for gallium and indium were 0.72 and 0.28 ng mL−1, respectively. The results showed the developed method was not susceptible to matrix effects, providing recoveries between 98% and 102%. The accuracy of the developed method was evaluated by the analysis of spiked certified reference materials. The developed method was successfully applied to gallium and indium determination in urine and lake water with satisfactory results.

Why it matters

OpenAlex reports 22 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple, sensitive, and selective method for the determination of gallium and indium in different samples at trace levels is presented. This method was based on complexation of analyzes with 2-(5-bromo-2- pyridylazo)-5-diethylaminophenol (5-Br-PADAP) in the presence of t-octylphenoxy-polyethoxyethanol (Triton X-100). After phase separation, the analyzed concentrations were determined by inductively coupled plasma optical emission spectrometry. Quantitative extraction of gallium and indium was performed at pH 7.0, 1.7 mmol L−1, 5-Br-PADAP, 1.3% (w/v) Triton X-100 and at 75°C. The relative standard deviations (RSD) of this method were between 0.3% and 1.6% (C = 20 ng mL−1, n = 9). The calibration curve is linear over the concentration range 6–200 ng mL−1 for gallium and 2–200 ng mL−1 for indium, respectively. The limits of detection (LOD) for gallium and indium were 0.72 and 0.28 ng mL−1, respectively. The results showed the developed method was not susceptible to matrix effects, providing recoveries between 98% and 102%. The accuracy of the developed method was evaluated by the analysis of spiked certified reference materials. The developed method was successfully applied to gallium and indium determination in urine and lake water with satisfactory results.

Key concepts: Chemistry, Gallium, Indium, Detection limit, Calibration curve, Analytical Chemistry (journal), Extraction (chemistry), Cloud point