2014Chemical Engineering CommunicationsRequires access

Residence Time and Concentration Distribution in a Kenics Static Mixer

Akbar Mohammadi, Jafarsadegh Moghaddas, Arman Ariamanesh

Open publisher page 12 citations

Abstract

Static mixers, often referred to as motionless mixers, are in-line mixing devices that consist of mixing elements inserted into a length of pipe. Most of the experimental works in this field have concentrated on establishing design guidelines and pressure drop correlations. Due to experimental difficulties, few articles have been published on the investigation of the flow and mixing mechanisms. In this work, a Kenics KMX static mixer was utilized to study concentration and residence time distribution (RTD) and effect of Reynolds number on mixing. The static mixer had six mixing elements arranged in-line along the length of the tube, and the angle between two neighboring elements was 90°. The length of the mixer was 0.98 m with internal and external diameters of 5.0 cm and 6.0 cm, respectively. The main continuous fluid was water, and NaCl solution was used as a tracer. All experiments were conducted with three replications at three Reynolds numbers, Re = 1188.71, 1584.95, and 1981.19. A dispersion model was used to model the RTD data. The experimental results were compared with the model results and reasonable agreement was achieved.

About this research paper

What this paper is about

Static mixers, often referred to as motionless mixers, are in-line mixing devices that consist of mixing elements inserted into a length of pipe. Most of the experimental works in this field have concentrated on establishing design guidelines and pressure drop correlations. Due to experimental difficulties, few articles have been published on the investigation of the flow and mixing mechanisms. In this work, a Kenics KMX static mixer was utilized to study concentration and residence time distribution (RTD) and effect of Reynolds number on mixing. The static mixer had six mixing elements arranged in-line along the length of the tube, and the angle between two neighboring elements was 90°. The length of the mixer was 0.98 m with internal and external diameters of 5.0 cm and 6.0 cm, respectively. The main continuous fluid was water, and NaCl solution was used as a tracer. All experiments were conducted with three replications at three Reynolds numbers, Re = 1188.71, 1584.95, and 1981.19. A dispersion model was used to model the RTD data. The experimental results were compared with the model results and reasonable agreement was achieved.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Static mixers, often referred to as motionless mixers, are in-line mixing devices that consist of mixing elements inserted into a length of pipe. Most of the experimental works in this field have concentrated on establishing design guidelines and pressure drop correlations. Due to experimental difficulties, few articles have been published on the investigation of the flow and mixing mechanisms. In this work, a Kenics KMX static mixer was utilized to study concentration and residence time distribution (RTD) and effect of Reynolds number on mixing. The static mixer had six mixing elements arranged in-line along the length of the tube, and the angle between two neighboring elements was 90°. The length of the mixer was 0.98 m with internal and external diameters of 5.0 cm and 6.0 cm, respectively. The main continuous fluid was water, and NaCl solution was used as a tracer. All experiments were conducted with three replications at three Reynolds numbers, Re = 1188.71, 1584.95, and 1981.19. A dispersion model was used to model the RTD data. The experimental results were compared with the model results and reasonable agreement was achieved.

Key concepts: Static mixer, Residence time distribution, Mechanics, Reynolds number, Mixing (physics), Agitator, TRACER, Pressure drop

Related papers

Back to paper searchBrowse research topicsOriginal source
Residence Time and Concentration Distribution in a Kenics Static Mixer — Research Paper | ScholarLens