2015Klinische Monatsblätter für AugenheilkundeRequires access

Predictability of Morphological Changes of the Anterior Chamber Angle after Laser Iridotomy by Ultrasound Biomicroscopy

Christoph Nützi, Selim Orgül, Andreas Schötzau, Matthias C. Grieshaber

Open publisher page 7 citations

Abstract

BACKGROUND: Laser peripheral iridotomy is a useful method in primary angle-closure eyes to prevent angle-closure attack and development of glaucomatous optic nerve damage. The aim of this study was to quantify morphological changes after LPI and their impact on intraocular pressure, and to evaluate predictive parameters for enlarging the anterior chamber angle after laser peripheral iridotomy. PATIENTS AND METHODS: Ultrasound biomicroscopy images and intraocular pressure before and after laser peripheral iridotomy from 62 eyes of 34 patients with primary angle-closure were retrospectively analysed. Anterior chamber angle, anterior chamber depth, lens thickness, iris curvature and a newly defined parameter, the end-iris-lens vault were measured. RESULTS: In each quadrant anterior chamber angle was on average significantly larger (at 12 o'clock: from 10.1° to 15.0°; at 3 o'clock: from 13.4° to 19.8°; at 6 o'clock: from 12.2° to 18.5°; at 9 o'clock: from 12.9 to 17.9°; p<0.001) and iris curvature significantly smaller (at 12 o'clock: from 0.26 mm to 0.10 mm; at 3 o'clock: from 0.21 mm to 0.08 mm; at 6 o'clock: from 0.25 mm to 0.08 mm; at 9 o'clock: from 0.21 mm to 0.08 mm; p<0.001) after laser peripheral iridotomy. Anterior chamber depth, lens thickness and end-iris-lens-vault did not significantly change. Anterior chamber angle in each quadrant (p<0.05), and iris curvature at 3 and 6 o'clock positions (p<0.05) were highly predictive for the enlargement of the anterior chamber angle after laser peripheral iridotomy. Intraocular pressure was slightly lower after laser peripheral iridotomy (from 16.6 mmHg to 16.1 mmHg). CONCLUSION: In primary angle-closure eyes, laser peripheral iridotomy enlarges the angle and flattens the iris significantly. This study demonstrated that a small anterior chamber angle and a large iris curvature are predictive parameters for a greater enlargement of the anterior chamber angle after laser peripheral iridotomy. These new findings underline the importance of the ultrasound biomicroscopy and may help in counselling patients about laser peripheral iridotomy.

About this research paper

What this paper is about

BACKGROUND: Laser peripheral iridotomy is a useful method in primary angle-closure eyes to prevent angle-closure attack and development of glaucomatous optic nerve damage. The aim of this study was to quantify morphological changes after LPI and their impact on intraocular pressure, and to evaluate predictive parameters for enlarging the anterior chamber angle after laser peripheral iridotomy. PATIENTS AND METHODS: Ultrasound biomicroscopy images and intraocular pressure before and after laser peripheral iridotomy from 62 eyes of 34 patients with primary angle-closure were retrospectively analysed. Anterior chamber angle, anterior chamber depth, lens thickness, iris curvature and a newly defined parameter, the end-iris-lens vault were measured. RESULTS: In each quadrant anterior chamber angle was on average significantly larger (at 12 o'clock: from 10.1° to 15.0°; at 3 o'clock: from 13.4° to 19.8°; at 6 o'clock: from 12.2° to 18.5°; at 9 o'clock: from 12.9 to 17.9°; p<0.001) and iris curvature significantly smaller (at 12 o'clock: from 0.26 mm to 0.10 mm; at 3 o'clock: from 0.21 mm to 0.08 mm; at 6 o'clock: from 0.25 mm to 0.08 mm; at 9 o'clock: from 0.21 mm to 0.08 mm; p<0.001) after laser peripheral iridotomy. Anterior chamber depth, lens thickness and end-iris-lens-vault did not significantly change. Anterior chamber angle in each quadrant (p<0.05), and iris curvature at 3 and 6 o'clock positions (p<0.05) were highly predictive for the enlargement of the anterior chamber angle after laser peripheral iridotomy. Intraocular pressure was slightly lower after laser peripheral iridotomy (from 16.6 mmHg to 16.1 mmHg). CONCLUSION: In primary angle-closure eyes, laser peripheral iridotomy enlarges the angle and flattens the iris significantly. This study demonstrated that a small anterior chamber angle and a large iris curvature are predictive parameters for a greater enlargement of the anterior chamber angle after laser peripheral iridotomy. These new findings underline the importance of the ultrasound biomicroscopy and may help in counselling patients about laser peripheral iridotomy.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Laser peripheral iridotomy is a useful method in primary angle-closure eyes to prevent angle-closure attack and development of glaucomatous optic nerve damage. The aim of this study was to quantify morphological changes after LPI and their impact on intraocular pressure, and to evaluate predictive parameters for enlarging the anterior chamber angle after laser peripheral iridotomy. PATIENTS AND METHODS: Ultrasound biomicroscopy images and intraocular pressure before and after laser peripheral iridotomy from 62 eyes of 34 patients with primary angle-closure were retrospectively analysed. Anterior chamber angle, anterior chamber depth, lens thickness, iris curvature and a newly defined parameter, the end-iris-lens vault were measured. RESULTS: In each quadrant anterior chamber angle was on average significantly larger (at 12 o'clock: from 10.1° to 15.0°; at 3 o'clock: from 13.4° to 19.8°; at 6 o'clock: from 12.2° to 18.5°; at 9 o'clock: from 12.9 to 17.9°; p<0.001) and iris curvature significantly smaller (at 12 o'clock: from 0.26 mm to 0.10 mm; at 3 o'clock: from 0.21 mm to 0.08 mm; at 6 o'clock: from 0.25 mm to 0.08 mm; at 9 o'clock: from 0.21 mm to 0.08 mm; p<0.001) after laser peripheral iridotomy. Anterior chamber depth, lens thickness and end-iris-lens-vault did not significantly change. Anterior chamber angle in each quadrant (p<0.05), and iris curvature at 3 and 6 o'clock positions (p<0.05) were highly predictive for the enlargement of the anterior chamber angle after laser peripheral iridotomy. Intraocular pressure was slightly lower after laser peripheral iridotomy (from 16.6 mmHg to 16.1 mmHg). CONCLUSION: In primary angle-closure eyes, laser peripheral iridotomy enlarges the angle and flattens the iris significantly. This study demonstrated that a small anterior chamber angle and a large iris curvature are predictive parameters for a greater enlargement of the anterior chamber angle after laser peripheral iridotomy. These new findings underline the importance of the ultrasound biomicroscopy and may help in counselling patients about laser peripheral iridotomy.

Key concepts: Ultrasound biomicroscopy, Quadrant (abdomen), IRIS (biosensor), Ophthalmology, Ultrasound, Medicine, Intraocular pressure, Lens (geology)

Related papers

Back to paper searchBrowse research topicsOriginal source
Predictability of Morphological Changes of the Anterior Chamber Angle after Laser Iridotomy by Ultrasound Biomicroscopy — Research Paper | ScholarLens