2012Advanced materials researchOpen access

Determination of Crystallite Size in Synthetic and Natural Hydroxyapatite: A Comparison between XRD and TEM Results

Soheila Sadat Rahavi, Ahmad Monshi, Rahmatollah Emadi, Ali Doostmohammadi, Hamed Akbarian

Open full text 29 citations

Abstract

The study reported here focuses on the crystallite size of synthetic hydroxyapatite (HAp) obtained using sol-gel method and natural HAp obtained by processing the natural bone. Human and camel bones were used for obtaining natural HAp. HAp particles were produced, characterized and compared for their crystallite size. The average crystallite size of the samples was derived from the X-ray Diffraction (XRD) data using the Scherrer formula and a new method called modified scherrer equation that was came by developing the Scherrer formula. The results showed the crystallite size of HAp gained from different sources were different. The crystallite size of synthetic, human and camel bone-derived HAp, were approximately 18, 23 and 29 nanometer, respectively. These values were less than those obtained from TEM images. It seems that calculated crystallite size using XRD data and Scherrer equations is less than the real size. This important finding must be taken into consideration in applying Scherrer equations.

About this research paper

What this paper is about

The study reported here focuses on the crystallite size of synthetic hydroxyapatite (HAp) obtained using sol-gel method and natural HAp obtained by processing the natural bone. Human and camel bones were used for obtaining natural HAp. HAp particles were produced, characterized and compared for their crystallite size. The average crystallite size of the samples was derived from the X-ray Diffraction (XRD) data using the Scherrer formula and a new method called modified scherrer equation that was came by developing the Scherrer formula. The results showed the crystallite size of HAp gained from different sources were different. The crystallite size of synthetic, human and camel bone-derived HAp, were approximately 18, 23 and 29 nanometer, respectively. These values were less than those obtained from TEM images. It seems that calculated crystallite size using XRD data and Scherrer equations is less than the real size. This important finding must be taken into consideration in applying Scherrer equations.

Why it matters

OpenAlex reports 29 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The study reported here focuses on the crystallite size of synthetic hydroxyapatite (HAp) obtained using sol-gel method and natural HAp obtained by processing the natural bone. Human and camel bones were used for obtaining natural HAp. HAp particles were produced, characterized and compared for their crystallite size. The average crystallite size of the samples was derived from the X-ray Diffraction (XRD) data using the Scherrer formula and a new method called modified scherrer equation that was came by developing the Scherrer formula. The results showed the crystallite size of HAp gained from different sources were different. The crystallite size of synthetic, human and camel bone-derived HAp, were approximately 18, 23 and 29 nanometer, respectively. These values were less than those obtained from TEM images. It seems that calculated crystallite size using XRD data and Scherrer equations is less than the real size. This important finding must be taken into consideration in applying Scherrer equations.

Key concepts: Scherrer equation, Crystallite, Materials science, Grain size, Diffraction, Crystallography, Analytical Chemistry (journal), Chemical engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Crystallite Size in Synthetic and Natural Hydroxyapatite: A Comparison between XRD and TEM Results — Research Paper | ScholarLens