Use of Synthetic Absorbable Sutures for Abdominal and Chest Wound Closure
Dwight H. Murray
Abstract
Dwight H. Murray
Abstract
The advent of synthetic collagen suture (polyglycolic acid and polyglacin 910) has provided a new dimension in surgical suturing. However, surgeons in general have not yet taken full advantage of the potential that this new material offers. Associated evisceration and wound dehiscence rates as well as the incidence rate of wound infection were assessed since these represent standards by which the suture material can be evaluated. In an entire series of 650 cases, there has been one case of wound dehiscence with evisceration. The incidence of infection has been less than 1%, which is comparable to previous experience with interrupted, nonabsorbable sutures. The time required for closure using the new material has been approximately one third of that associated with the use of conventional interrupted closure sutures. This implies a substantial cost reduction for the patient. As a result of this experience, the synthetic absorbable sutures seem to represent the material of choice for routine abdominal or chest wound closure.
OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The advent of synthetic collagen suture (polyglycolic acid and polyglacin 910) has provided a new dimension in surgical suturing. However, surgeons in general have not yet taken full advantage of the potential that this new material offers. Associated evisceration and wound dehiscence rates as well as the incidence rate of wound infection were assessed since these represent standards by which the suture material can be evaluated. In an entire series of 650 cases, there has been one case of wound dehiscence with evisceration. The incidence of infection has been less than 1%, which is comparable to previous experience with interrupted, nonabsorbable sutures. The time required for closure using the new material has been approximately one third of that associated with the use of conventional interrupted closure sutures. This implies a substantial cost reduction for the patient. As a result of this experience, the synthetic absorbable sutures seem to represent the material of choice for routine abdominal or chest wound closure.
Key concepts: Medicine, Surgery, Evisceration (ophthalmology), Abdominal wound, Dehiscence, Wound dehiscence, Wound closure, Absorbable suture