1993American Journal of Physical AnthropologyRequires access

Brief communication: Measurement size, precision, and reliability in craniofacial anthropometry: Bigger is better

Paul L. Jamison, Richard E. Ward

Open publisher page 69 citations

Abstract

In this paper we examine the results of an intraobserver measurement error study involving 49 craniofacial variables that ranged in size from less than 1 cm to approximately 20 cm. Repeat measurements were taken on 10 male and 10 female adult subjects (19-59 years old). Our focus is on the relationship between measurement size and measurement error across the 49 variables. We found that the size of the variable showed no relationship with the magnitude of the error as measured by the technical error of measurement. When the error was expressed as a coefficient of relative variation (Malina et al.: Vital and Health Statistics, Series 11, No. 23. Washington, DC: US Department of Health and Human Services, 1973), this quantity was negatively associated with the size of the measurement. Conversely, reliability (Fleiss: The Design and Analysis of Experiments. New York: John Wiley & Sons, 1986) was positively correlated with measurement size. We did not find effects of scale (Marks et al.: Am. J. Epidemiol. 130:578-587, 1989) within the individual measurements. Thus, for the range of size of the craniofacial measurements in this study, measurement size must be added to the list of factors such as ease of locating landmarks, measurement technique, and systematic bias in the application of the technique that can affect precision and reliability in anthropometry.

About this research paper

What this paper is about

In this paper we examine the results of an intraobserver measurement error study involving 49 craniofacial variables that ranged in size from less than 1 cm to approximately 20 cm. Repeat measurements were taken on 10 male and 10 female adult subjects (19-59 years old). Our focus is on the relationship between measurement size and measurement error across the 49 variables. We found that the size of the variable showed no relationship with the magnitude of the error as measured by the technical error of measurement. When the error was expressed as a coefficient of relative variation (Malina et al.: Vital and Health Statistics, Series 11, No. 23. Washington, DC: US Department of Health and Human Services, 1973), this quantity was negatively associated with the size of the measurement. Conversely, reliability (Fleiss: The Design and Analysis of Experiments. New York: John Wiley & Sons, 1986) was positively correlated with measurement size. We did not find effects of scale (Marks et al.: Am. J. Epidemiol. 130:578-587, 1989) within the individual measurements. Thus, for the range of size of the craniofacial measurements in this study, measurement size must be added to the list of factors such as ease of locating landmarks, measurement technique, and systematic bias in the application of the technique that can affect precision and reliability in anthropometry.

Why it matters

OpenAlex reports 69 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this paper we examine the results of an intraobserver measurement error study involving 49 craniofacial variables that ranged in size from less than 1 cm to approximately 20 cm. Repeat measurements were taken on 10 male and 10 female adult subjects (19-59 years old). Our focus is on the relationship between measurement size and measurement error across the 49 variables. We found that the size of the variable showed no relationship with the magnitude of the error as measured by the technical error of measurement. When the error was expressed as a coefficient of relative variation (Malina et al.: Vital and Health Statistics, Series 11, No. 23. Washington, DC: US Department of Health and Human Services, 1973), this quantity was negatively associated with the size of the measurement. Conversely, reliability (Fleiss: The Design and Analysis of Experiments. New York: John Wiley & Sons, 1986) was positively correlated with measurement size. We did not find effects of scale (Marks et al.: Am. J. Epidemiol. 130:578-587, 1989) within the individual measurements. Thus, for the range of size of the craniofacial measurements in this study, measurement size must be added to the list of factors such as ease of locating landmarks, measurement technique, and systematic bias in the application of the technique that can affect precision and reliability in anthropometry.

Key concepts: Statistics, Anthropometry, Observational error, Reliability (semiconductor), Craniofacial, Mathematics, Range (aeronautics), Psychology

Related papers

Back to paper searchBrowse research topicsOriginal source
Brief communication: Measurement size, precision, and reliability in craniofacial anthropometry: Bigger is better — Research Paper | ScholarLens