EOS ASTER thermal infrared band vicarious calibration
F. D. Palluconi, Hideyuki Tonooka, Simon J. Hook, Ali Abtahi, R. E. Alley, Tim Thompson, Gordon Hoover, Serj Zadourian
Abstract
F. D. Palluconi, Hideyuki Tonooka, Simon J. Hook, Ali Abtahi, R. E. Alley, Tim Thompson, Gordon Hoover, Serj Zadourian
Abstract
Calibration of the five EOS ASTER instrument emission bands (90 m pixels at surface) is being checked during the operational life of the mission using field measurements simultaneous with the image acquisition. For water targets, radiometers, temperature measuring buoys and local radiosonde atmospheric profiles are used to determine the average water surface kinetic temperature over areas roughly 3 X 3 pixels in size. The in-band surface leaving radiance is then projected through the atmosphere using the MODTRAN radiation transfer code allowing an at sensor radiance comparison. The instrument at sensor radiance is also projected to the water surface allowing a comparison in terms of water surface kinetic temperature. Over the first year of operation, the field measurement derived at sensor radiance agrees with the image derived radiance to better than plus/minus 1% for all five bands indicating both stable and accurate operation.
OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Calibration of the five EOS ASTER instrument emission bands (90 m pixels at surface) is being checked during the operational life of the mission using field measurements simultaneous with the image acquisition. For water targets, radiometers, temperature measuring buoys and local radiosonde atmospheric profiles are used to determine the average water surface kinetic temperature over areas roughly 3 X 3 pixels in size. The in-band surface leaving radiance is then projected through the atmosphere using the MODTRAN radiation transfer code allowing an at sensor radiance comparison. The instrument at sensor radiance is also projected to the water surface allowing a comparison in terms of water surface kinetic temperature. Over the first year of operation, the field measurement derived at sensor radiance agrees with the image derived radiance to better than plus/minus 1% for all five bands indicating both stable and accurate operation.
Key concepts: Radiance, MODTRAN, Remote sensing, Pixel, Environmental science, Radiosonde, Calibration, Radiometer