1999•Unpublished venueRequires access

Computer investigation of voltage effect on electrical treeing

М. Д. Носков

Open publisher page 1 citations

Abstract

The propagation of electrical tree channels into dielectrics with the subsequent breakdown of the electrode gap is one of the main causes for failure of high voltage insulation systems. The tree growth occurs s in regions of high electric field due to the accumulation of dielectric material damage, The damage is caused by partial discharges within the gas-filled tree channels, Dissado and Fothergill [1]. The parameters of the partial discharge activity depend on the electrical tree shape and growth mode. The partial discharges and the tree growth are simultaneous and selfconsistent processes resulting in insulation degradation. It is desirable to have a self-consistent model, which involves both electrical tree growth with local electrical fields and partial discharge events within the growing tree channels. This self-consistent model has been previously introduced in order to describe the simultaneous tree growth and partial discharge activity in solid insulation under AC voltages by Malinovski et al [2]. In the present paper the suggested approach is extended to more thoroughly investigate the effect of applied voltage on the spatial and temporal development of electrical trees and partial discharge characteristics.

About this research paper

What this paper is about

The propagation of electrical tree channels into dielectrics with the subsequent breakdown of the electrode gap is one of the main causes for failure of high voltage insulation systems. The tree growth occurs s in regions of high electric field due to the accumulation of dielectric material damage, The damage is caused by partial discharges within the gas-filled tree channels, Dissado and Fothergill [1]. The parameters of the partial discharge activity depend on the electrical tree shape and growth mode. The partial discharges and the tree growth are simultaneous and selfconsistent processes resulting in insulation degradation. It is desirable to have a self-consistent model, which involves both electrical tree growth with local electrical fields and partial discharge events within the growing tree channels. This self-consistent model has been previously introduced in order to describe the simultaneous tree growth and partial discharge activity in solid insulation under AC voltages by Malinovski et al [2]. In the present paper the suggested approach is extended to more thoroughly investigate the effect of applied voltage on the spatial and temporal development of electrical trees and partial discharge characteristics.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The propagation of electrical tree channels into dielectrics with the subsequent breakdown of the electrode gap is one of the main causes for failure of high voltage insulation systems. The tree growth occurs s in regions of high electric field due to the accumulation of dielectric material damage, The damage is caused by partial discharges within the gas-filled tree channels, Dissado and Fothergill [1]. The parameters of the partial discharge activity depend on the electrical tree shape and growth mode. The partial discharges and the tree growth are simultaneous and selfconsistent processes resulting in insulation degradation. It is desirable to have a self-consistent model, which involves both electrical tree growth with local electrical fields and partial discharge events within the growing tree channels. This self-consistent model has been previously introduced in order to describe the simultaneous tree growth and partial discharge activity in solid insulation under AC voltages by Malinovski et al [2]. In the present paper the suggested approach is extended to more thoroughly investigate the effect of applied voltage on the spatial and temporal development of electrical trees and partial discharge characteristics.

Key concepts: Electrical treeing, Voltage, Materials science, Electrical engineering, Computer science, Engineering, Partial discharge

Related papers

Back to paper searchBrowse research topicsOriginal source
Computer investigation of voltage effect on electrical treeing — Research Paper | ScholarLens