2005•Journal Of Clinical PeriodontologyRequires access

Bone reactions to longstanding functional load at implants: an experimental study in dogs

Tord Berglundh, Ingemar Abrahamsson, Jan Lindhe

Open publisher page 180 citations

Abstract

OBJECTIVES: The aims of the present investigation were (i) to study marginal bone level alterations following implant installation, abutment connection and functional loading and (ii) to analyse bone tissue reactions to functional load. MATERIAL AND METHODS: Six beagle dogs, about 1-year old, were used. All mandibular pre-molars were extracted. Three months later four implants of the Astra Tech Implants Dental System were installed in one side of the mandible and four standard fixtures of the Brånemark System were placed in the contralateral side of the mandible. Abutment connection was performed 3 months later and a plaque control programme was initiated. Three months after abutment connection fixed partial dentures (FPDs) made in gold were cemented to the maxillary canines and pre-molars. FPDs were also connected to the three posterior implants in each side of the mandible, while the mesial implant in each side was used as an unloaded control. Radiographs were obtained from all implant sites following implant installation, abutment connection and FPD placement. Ten months after the FPD placement the radiographic examination was repeated. The animals were sacrificed and biopsies from all implant sites were obtained and prepared for histological analysis. RESULTS: The radiographic analysis revealed that largest amount of bone loss occurred following implant installation and abutment connection and that this loss was more pronounced at Brånemark than at Astra implants. The bone level alterations that were observed at implants exposed to 10 months of functional load in both implant systems were small and did not differ from control sites. The histological analysis revealed that implants exposed to functional load exhibited a higher degree of bone-to-implant contact than control implants in both implant systems. CONCLUSION: It is suggested that functional load at implants may enhance osseointegration and does not result in marginal bone loss.

About this research paper

What this paper is about

OBJECTIVES: The aims of the present investigation were (i) to study marginal bone level alterations following implant installation, abutment connection and functional loading and (ii) to analyse bone tissue reactions to functional load. MATERIAL AND METHODS: Six beagle dogs, about 1-year old, were used. All mandibular pre-molars were extracted. Three months later four implants of the Astra Tech Implants Dental System were installed in one side of the mandible and four standard fixtures of the Brånemark System were placed in the contralateral side of the mandible. Abutment connection was performed 3 months later and a plaque control programme was initiated. Three months after abutment connection fixed partial dentures (FPDs) made in gold were cemented to the maxillary canines and pre-molars. FPDs were also connected to the three posterior implants in each side of the mandible, while the mesial implant in each side was used as an unloaded control. Radiographs were obtained from all implant sites following implant installation, abutment connection and FPD placement. Ten months after the FPD placement the radiographic examination was repeated. The animals were sacrificed and biopsies from all implant sites were obtained and prepared for histological analysis. RESULTS: The radiographic analysis revealed that largest amount of bone loss occurred following implant installation and abutment connection and that this loss was more pronounced at Brånemark than at Astra implants. The bone level alterations that were observed at implants exposed to 10 months of functional load in both implant systems were small and did not differ from control sites. The histological analysis revealed that implants exposed to functional load exhibited a higher degree of bone-to-implant contact than control implants in both implant systems. CONCLUSION: It is suggested that functional load at implants may enhance osseointegration and does not result in marginal bone loss.

Why it matters

OpenAlex reports 180 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVES: The aims of the present investigation were (i) to study marginal bone level alterations following implant installation, abutment connection and functional loading and (ii) to analyse bone tissue reactions to functional load. MATERIAL AND METHODS: Six beagle dogs, about 1-year old, were used. All mandibular pre-molars were extracted. Three months later four implants of the Astra Tech Implants Dental System were installed in one side of the mandible and four standard fixtures of the Brånemark System were placed in the contralateral side of the mandible. Abutment connection was performed 3 months later and a plaque control programme was initiated. Three months after abutment connection fixed partial dentures (FPDs) made in gold were cemented to the maxillary canines and pre-molars. FPDs were also connected to the three posterior implants in each side of the mandible, while the mesial implant in each side was used as an unloaded control. Radiographs were obtained from all implant sites following implant installation, abutment connection and FPD placement. Ten months after the FPD placement the radiographic examination was repeated. The animals were sacrificed and biopsies from all implant sites were obtained and prepared for histological analysis. RESULTS: The radiographic analysis revealed that largest amount of bone loss occurred following implant installation and abutment connection and that this loss was more pronounced at Brånemark than at Astra implants. The bone level alterations that were observed at implants exposed to 10 months of functional load in both implant systems were small and did not differ from control sites. The histological analysis revealed that implants exposed to functional load exhibited a higher degree of bone-to-implant contact than control implants in both implant systems. CONCLUSION: It is suggested that functional load at implants may enhance osseointegration and does not result in marginal bone loss.

Key concepts: Medicine, Dentistry, Orthodontics

Related papers

Back to paper searchBrowse research topicsOriginal source
Bone reactions to longstanding functional load at implants: an experimental study in dogs — Research Paper | ScholarLens