Methionine – Au Nanoparticle Modified Glassy Carbon Electrode: a Novel Platform for Electrochemical Detection of Hydroquinone
Jiahong He, Song Zhong-rong, Shengtao Zhang, Lin Wang, Ying ZHANG, Ri Qiu
Abstract
Jiahong He, Song Zhong-rong, Shengtao Zhang, Lin Wang, Ying ZHANG, Ri Qiu
Abstract
A high sensitive electrochemical sensor based on methionine/gold nanoparticles (MET/AuNPs) modified glassy carbon electrode (GCE) was fabricated for the quantitative detection of hydroquinone (HQ). The as-modified electrode was characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD) techniques. The electrochemical performance of the sensor to HQ was investigated by using cyclic and differential pulse voltammetry, which revealed its excellent electrocatalytic activity and reversibility towards HQ. The separation of anodic and cathodic peak (∆Ep) was decreased from 471 mV to 75 mV. The anodic peak current achieved under the optimum conditions was linear with the HQ concentration ranging from 8 μM to 400 μM with the detection limit 0.12 μM (3σ). The as-fabricated sensor also showed a good selectivity towards HQ without demonstrating interference from other coexisting species. Furthermore, the sensor showed a good performance for HQ detection in environmental water, which suggests its potential practical application. DOI: http://dx.doi.org/10.5755/j01.ms.20.4.6477
OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A high sensitive electrochemical sensor based on methionine/gold nanoparticles (MET/AuNPs) modified glassy carbon electrode (GCE) was fabricated for the quantitative detection of hydroquinone (HQ). The as-modified electrode was characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD) techniques. The electrochemical performance of the sensor to HQ was investigated by using cyclic and differential pulse voltammetry, which revealed its excellent electrocatalytic activity and reversibility towards HQ. The separation of anodic and cathodic peak (∆Ep) was decreased from 471 mV to 75 mV. The anodic peak current achieved under the optimum conditions was linear with the HQ concentration ranging from 8 μM to 400 μM with the detection limit 0.12 μM (3σ). The as-fabricated sensor also showed a good selectivity towards HQ without demonstrating interference from other coexisting species. Furthermore, the sensor showed a good performance for HQ detection in environmental water, which suggests its potential practical application. DOI: http://dx.doi.org/10.5755/j01.ms.20.4.6477
Key concepts: Materials science, Detection limit, Hydroquinone, Electrochemical gas sensor, Differential pulse voltammetry, Electrochemistry, Electrode, Cyclic voltammetry