2014•Materials ScienceOpen access

Methionine – Au Nanoparticle Modified Glassy Carbon Electrode: a Novel Platform for Electrochemical Detection of Hydroquinone

Jiahong He, Song Zhong-rong, Shengtao Zhang, Lin Wang, Ying ZHANG, Ri Qiu

Open full text 5 citations

Abstract

A high sensitive electrochemical sensor based on methionine/gold nanoparticles (MET/AuNPs) modified glassy carbon electrode (GCE) was fabricated for the quantitative detection of hydroquinone (HQ). The as-modified electrode was characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD) techniques. The electrochemical performance of the sensor to HQ was investigated by using cyclic and differential pulse voltammetry, which revealed its excellent electrocatalytic activity and reversibility towards HQ. The separation of anodic and cathodic peak (∆Ep) was decreased from 471 mV to 75 mV. The anodic peak current achieved under the optimum conditions was linear with the HQ concentration ranging from 8 μM to 400 μM with the detection limit 0.12 μM (3σ). The as-fabricated sensor also showed a good selectivity towards HQ without demonstrating interference from other coexisting species. Furthermore, the sensor showed a good performance for HQ detection in environmental water, which suggests its potential practical application. DOI: http://dx.doi.org/10.5755/j01.ms.20.4.6477

About this research paper

What this paper is about

A high sensitive electrochemical sensor based on methionine/gold nanoparticles (MET/AuNPs) modified glassy carbon electrode (GCE) was fabricated for the quantitative detection of hydroquinone (HQ). The as-modified electrode was characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD) techniques. The electrochemical performance of the sensor to HQ was investigated by using cyclic and differential pulse voltammetry, which revealed its excellent electrocatalytic activity and reversibility towards HQ. The separation of anodic and cathodic peak (∆Ep) was decreased from 471 mV to 75 mV. The anodic peak current achieved under the optimum conditions was linear with the HQ concentration ranging from 8 μM to 400 μM with the detection limit 0.12 μM (3σ). The as-fabricated sensor also showed a good selectivity towards HQ without demonstrating interference from other coexisting species. Furthermore, the sensor showed a good performance for HQ detection in environmental water, which suggests its potential practical application. DOI: http://dx.doi.org/10.5755/j01.ms.20.4.6477

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A high sensitive electrochemical sensor based on methionine/gold nanoparticles (MET/AuNPs) modified glassy carbon electrode (GCE) was fabricated for the quantitative detection of hydroquinone (HQ). The as-modified electrode was characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD) techniques. The electrochemical performance of the sensor to HQ was investigated by using cyclic and differential pulse voltammetry, which revealed its excellent electrocatalytic activity and reversibility towards HQ. The separation of anodic and cathodic peak (∆Ep) was decreased from 471 mV to 75 mV. The anodic peak current achieved under the optimum conditions was linear with the HQ concentration ranging from 8 μM to 400 μM with the detection limit 0.12 μM (3σ). The as-fabricated sensor also showed a good selectivity towards HQ without demonstrating interference from other coexisting species. Furthermore, the sensor showed a good performance for HQ detection in environmental water, which suggests its potential practical application. DOI: http://dx.doi.org/10.5755/j01.ms.20.4.6477

Key concepts: Materials science, Detection limit, Hydroquinone, Electrochemical gas sensor, Differential pulse voltammetry, Electrochemistry, Electrode, Cyclic voltammetry

Related papers

Back to paper searchBrowse research topicsOriginal source
Methionine – Au Nanoparticle Modified Glassy Carbon Electrode: a Novel Platform for Electrochemical Detection of Hydroquinone — Research Paper | ScholarLens